Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/128669
Full metadata record
DC FieldValueLanguage
dc.creatorBianca Sousa Barros
dc.date.accessioned2025-11-11T15:35:57Z-
dc.date.available2025-11-11T15:35:57Z-
dc.date.issued2020-06-03
dc.date.submitted2020-03-24
dc.identifier.othersigarra:414270
dc.identifier.urihttps://hdl.handle.net/10216/128669-
dc.descriptionIntrodução: A Artroplastia Invertida do Ombro depende do músculo Deltoide em termos funcionais e de estabilidade. A tensão do Deltoide e as condições pré e pós-operatórias são fatores chave. Apesar de estarem descritos bons resultados subjetivos, os resultados funcionais revelam-se variáveis. O objetivo deste estudo é compreender as implicações biomecânicas e funcionais da Artroplastia Invertida do Ombro. Métodos: Quinze participantes após Artroplastia Invertida do Ombro unilateral foram avaliados com um dinamómetro isocinético (Abdução/Adução e Flexão Anterior/Extensão), Eletromiografia e Score de Constant-Murley. O braço sem prótese foi considerado o melhor estado funcional e usado como termo de comparação. Foi medido o comprimento do braço e calculada a diferença entre braços. Os participantes foram divididos em dois grupos de acordo com o Score de Constant-Murley do braço sem prótese: Grupo 1 (superior/igual a 80) e Grupo 1 (inferior a 80). Resultados: Foram observadas diferenças significativas nos parâmetros isocinéticos, especialmente no Grupo 0, obtendo melhores resultados o braço sem prótese. A Eletromiografia revelou que no Grupo 0 existe na globalidade uma menor atividade eletromiográfica no braço com prótese, principalmente nas porções Anterior e Média do músculo Deltoide, na Abdução e na Flexão Anterior. O Grupo 1 revelou menos diferenças significativas. Interpretação: A avaliação isocinética combinada com a Eletromiografia é uma ferramenta útil para avaliar resultados a nível muscular e articular. Este estudo demonstrou que a Artroplastia Invertida do Ombro tem um efeito significativo na amplitude de movimento na articulação do ombro e na força produzida no músculo Deltoide. Os ombros com prótese apresentaram resultados inferiores, contudo estas diferenças poderão só ser significativas aquando de um maior nível funcional. Palavras-chave: Deltoide, Artroplastia Invertida do Ombro, Isocinética, Eletromiografia de superfície.
dc.description.abstractBackground: Reverse Shoulder Arthroplasty depends on the Deltoid muscle to improve function and stability of the shoulder. Deltoid tension and pre- and postoperative conditions are key factors. Although good subjective results are reported, functional outcomes have shown variable improvements. The purpose of this study is to understand the biomechanical and functional influence of the Reverse Shoulder Arthroplasty. Methods: Fifteen participants after unilateral Reverse Shoulder Arthroplasty, were evaluated with isokinetic dynamometer (Abduction/Adduction and Forward Flexion/Extension), Electromyography and Constant-Murley Score. The arm without the prosthesis was considered the best performance status and used as comparison. Arm-length was measured and calculated the difference between arms. Participants were divided in two groups according to Constant-Murley Score of the arm without prosthesis: Group 0 (superior/equal to 80) and Group 1 (inferior to 80). Findings: Significant differences in isokinetic parameters were observed, especially in Group 0, with the arm without prosthesis having better results. The Electromyography showed that Group 0 has an overall decrease of the electromyography activity in the arm with prosthesis, especially in the anterior and middle portion of the Deltoid, in Abduction and Forward Flexion. Group 1 revealed less significant differences. Interpretation: Isokinetic evaluation combined with Electromyography is a useful tool to assess muscular and joint outcomes. This study demonstrated that Reverse Shoulder Arthroplasty has a significant effect in range of motion and strength of the shoulder joint and the Deltoid. Shoulders with the prosthesis presented worse performance, but these changes may only be significant when a higher functional level is present.
dc.language.isoeng
dc.rightsopenAccess
dc.subjectCiências médicas e da saúde
dc.subjectMedical and Health sciences
dc.titleAvaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
dc.typeDissertação
dc.contributor.uportoFaculdade de Medicina
dc.identifier.doi10.34626/p8q2-4y45
dc.identifier.tid202612872
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
thesis.degree.disciplineMestrado Integrado em Medicina
thesis.degree.grantorFaculdade de Medicina
thesis.degree.grantorUniversidade do Porto
thesis.degree.level1
Appears in Collections:FMUP - Dissertação

Files in This Item:
File Description SizeFormat 
414270.pdfIsokinetic Evaluation of the Deltoid Muscle After Reverse Shoulder Arthroplasty2.78 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.