Utilize este identificador para referenciar este registo: https://hdl.handle.net/10216/99069
Registo completo
Campo DCValorIdioma
dc.creatorMario Jorge Dinis Ribeiro
dc.creatorRicardo Cruz Correia
dc.creatorCristina Santos
dc.creatorSonia Fernandes
dc.creatorErnesto Palhares
dc.creatorRui Almeida Silva
dc.creatorPedro Amaro
dc.creatorMiguel Areia
dc.creatorAltamiro Costa Pereira
dc.creatorLuis Moreira Dias
dc.date.accessioned2022-09-07T16:13:40Z-
dc.date.available2022-09-07T16:13:40Z-
dc.date.issued2008
dc.identifier.issn1007-9327
dc.identifier.othersigarra:78987
dc.identifier.urihttps://hdl.handle.net/10216/99069-
dc.description.abstractAIM: To evaluate the use of web-based technologies to assess the learning curve and reassess reproducibility of a simplified version of a classification for gastric magnification chromoendoscopy (MC). METHODS: As part of a multicenter trial, a hybrid approach was taken using a CD-ROM, with 20 films of MC lasting 5 s each and an "autorun" file triggering a local HTML frameset referenced to a remote questionnaire through an Internet connection. Three endoscopists were asked to prospectively and independently classify 10 of these films randomly selected with at least 3 d apart. The answers were centrally stored and returned to participants together with adequate feedback with the right answer. RESULTS: For classification in 3 groups, both intra- [Cohen's kappa (kappa) = 0.79-1.00 to 0.89-1.00] and inter-observer agreement increased from 1st (moderate) to 6th observation (kappa = 0.94). Also, agreement with reference increased in the last observations (0.90, 1.00 and 1.00, for observers A, B and C, respectively). Validity of 100% was obtained by all observers at their 4th observation. When a 4th (sub)group was considered, inter-observer agreement was almost perfect (kappa = 0.92) at 6th observation. The relation with reference clearly improved into is (0.93-1.00) and sensitivity (75%-100%) at their 6th observations. CONCLUSION: This MC classification seems to be easily explainable and learnable as shown by excellent intra- and inter-observer agreement, and improved agreement with reference. A web system such as the one used in this study may be useful for endoscopic or other image based diagnostic procedures with respect to definition, education and dissemination.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectMedicina clínica
dc.subjectClinical medicine
dc.titleWeb-based system for training and dissemination of a magnification chromoendoscopy classification
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Medicina
dc.identifier.doi10.3748/wjg.14.7086
dc.identifier.authenticusP-003-T8E
dc.subject.fosCiências médicas e da saúde::Medicina clínica
dc.subject.fosMedical and Health sciences::Clinical medicine
Aparece nas coleções:FMUP - Artigo em Revista Científica Internacional

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
78987.pdf
  Restricted Access
812.14 kBAdobe PDFVer/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.