Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/91804
Full metadata record
DC FieldValueLanguage
dc.creatorGuerra, RS
dc.creatorAmaral, TF
dc.date.accessioned2024-07-12T23:16:34Z-
dc.date.available2024-07-12T23:16:34Z-
dc.date.issued2009
dc.identifier.issn1279-7707
dc.identifier.othersigarra:47308
dc.identifier.urihttps://hdl.handle.net/10216/91804-
dc.description.abstractObjective: Some dynamometers previously tested in healthy adults showed variable degrees of practicality, weight and ergonomics. More practical models could also be used as a more suitable tool in gerontological field and clinical studies. The purpose of the present study was to evaluate the reliability of the measurements and the performance of hand grip strength dynamometers in the elderly. Study design: Cross-sectional study. Setting: A retirement home and a social day care centre for old people in Porto, Portugal. Participants and measurements: The accuracy of four static grip strength dynamometers (Smedlay's (R) Hand, Sammons Preston Rolyan (R) Bulb, Eisenhut (R) and the Jamar (R) Hydraulic Hand) was first tested in laboratory. The grip strength of fifty-five elderly individuals 65-99 years was measured with the four dynamometers and the Jamar (R) Hydraulic Hand which was used as the comparison dynamometer. Results: The accuracy of the four dynamometers measurements compared to known forces was excellent (r > 0.96). A strong association between the measurements obtained by the Jamar (R) Hydraulic and the other instruments evaluated was found (r > 0.77) but significant differences between the mean hand grip strength values evaluated with the Jamar (R) Hydraulic and each one of the other dynamometers were found. The Bland and Altman plots confirmed that none of the three dynamometers reflects a good agreement with the Jamar (R) Hydraulic. Conclusion: All four dynamometers showed excellent results regarding their laboratory tested accuracy. However, their application among elderly people rendered very different results. The Smedlay's (R) results' were closer to the Jamar (R) Hydraulic, though none of these three dynamometers produced comparable results to the Jamar (R) Hydraulic.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectMedicina clínica
dc.subjectClinical medicine
dc.titleCOMPARISON OF HAND DYNAMOMETERS IN ELDERLY PEOPLE
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Ciências da Nutrição e Alimentação
dc.identifier.doi10.1007/s12603-009-0250-3
dc.identifier.authenticusP-003-E28
dc.subject.fosCiências médicas e da saúde::Medicina clínica
dc.subject.fosMedical and Health sciences::Clinical medicine
Appears in Collections:FCNAUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
47308.pdf
  Restricted Access
415.72 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.