Utilize este identificador para referenciar este registo: https://hdl.handle.net/10216/168446
Registo completo
Campo DCValorIdioma
dc.creatorSilva, Tiago
dc.creatorPoínhos, Rui
dc.creatorSardinha, L.B.
dc.creatorTeixeira, Vitor Hugo
dc.creatorSilva, A.M.
dc.date.accessioned2025-08-02T23:06:50Z-
dc.date.available2025-08-02T23:06:50Z-
dc.date.issued2025
dc.identifier.issn0905-7188
dc.identifier.othersigarra:721934
dc.identifier.urihttps://hdl.handle.net/10216/168446-
dc.description.abstractThe criterion four-compartment (4C) model combines dual-energy x-ray absorptiometry (DXA), deuterium dilution, and air displacement plethysmography (ADP), but its complexity limits practicality. This study aimed to externally validate a DXA-derived body volume (BV) equation (DXA-BVSilva) and assess the accuracy of a rapid 4C model replacing deuterium dilution total body water (TBW) with bioelectrical impedance spectroscopy (BIS) alongside DXA-derived BV in athletes. A total of 143 athletes (27.3% females) validated DXA-BV, with 115 (33.9% females) assessed for FM. Criterion 4C used DXA for bone mineral content, ADP for BV, and deuterium dilution for TBW. Several rapid 4C models were tested. DXA-BVSilva and DXA-BVHeymsfield reliably estimated BV, showing minimal mean differences and narrow 95% limits of agreement (LOA) compared to ADP. Among rapid 4C models, 4CTBWBIS, 4C BVSilvaTBWBIS, and 4C BVHeymsfieldTBWBIS provided the most accurate FM estimates with small, nonsignificant differences to the criterion (MD [SD]: -0.18 [1.25] kg; -0.23 [1.82] kg; 0.18 [1.87] kg, respectively) and narrow 95% LOA (-2.62 to 2.27, -3.79 to 3.33 and - 3.48 to 3.83 kg, respectively) with no proportional bias. This research supports the implementation of rapid 4C models in settings where the criterion 4C model is impractical. By improving accuracy in body composition assessment, our findings have implications for sports nutrition, sports science, and academic research, offering a viable alternative to traditional 2C and 3C models (DXA).
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectCiências da Saúde, Ciências médicas e da saúde
dc.subjectHealth sciences, Medical and Health sciences
dc.titleRapid Four-Compartment Models in Athletes Using Alternative Solutions for Body Volume and Water
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Ciências da Nutrição e Alimentação
dc.identifier.doi10.1111/sms.70062
dc.identifier.authenticusP-018-RCP
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Aparece nas coleções:FCNAUP - Artigo em Revista Científica Internacional

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
721934.pdf
  Restricted Access
264.62 kBAdobe PDFVer/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.