Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/168441
Author(s): de Oliveira, G.B.
Fernandes, L.V.
Amaral, Teresa
Vasques, A.C.J.
Corona, L.P.
Title: Validity and reliability of Gripwise digital dynamometer in the assessment of handgrip strength in older adults
Issue Date: 2025
Abstract: Introduction With the advancement of studies on the importance of sarcopenia in the aging process, new technologies have been developed to assess muscle mass and function. However, most research on portable devices has not considered a wide range of ages and clinical conditions. This study aimed to evaluate the reliability of the Gripwise digital dynamometer in measuring handgrip strength in older Brazilian adults, comparing its performance with the widely used Saehan device.Methods A cross-sectional study was conducted with 149 participants (32 men and 117 women), with an average age of 69.5 years. Handgrip strength was measured using both the Gripwise and Saehan dynamometers. Reliability was assessed using the intraclass correlation coefficient (ICC). Analyses considered three handgrip strength measurements from both devices, as well as the highest value obtained. The classification of dynapenia (low muscle strength) was compared using different cutoff points proposed by Villain et al. (2023), Spexoto et al. (2022), and Cruz-Jentoft et al. (2019).Results Both dynamometers demonstrated excellent reliability, with ICC values above 0.90. However, significant differences in mean handgrip strength values were observed between the devices (approximately 3.5-four kgf). These variations impacted the classification of dynapenia, with the Gripwise identifying more cases of low muscle strength compared to Saehan.Conclusion The lower values reported by the Gripwise may impact clinical decision-making in two ways. On one hand, lower values may lead to earlier detection of muscle weakness, allowing for quicker intervention in individuals with strength below typical thresholds. However, this could also result in an overestimation of the prevalence of dynapenia if the values do not accurately reflect true muscle strength, which could lead to unnecessary interventions. Therefore, it is crucial to consider the need for adjustments in the cutoff points when using Gripwise. These findings highlight the need to revise cutoff points for dynapenia classification, considering device variations and model differences in older age groups.
Subject: Ciências da Saúde, Ciências médicas e da saúde
Health sciences, Medical and Health sciences
Scientific areas: Ciências médicas e da saúde
Medical and Health sciences
DOI: 10.3389/fragi.2025.1560097
URI: https://hdl.handle.net/10216/168441
Document Type: Artigo em Revista Científica Internacional
Rights: openAccess
Appears in Collections:FCNAUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
733675.pdf734.96 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.