Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10216/166973Registo completo
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.creator | Maria Lopes Teixeira de Sousa Oliveira | |
| dc.date.accessioned | 2026-01-26T05:14:54Z | - |
| dc.date.available | 2026-01-26T05:14:54Z | - |
| dc.date.issued | 2025-05-13 | |
| dc.date.submitted | 2025-03-21 | |
| dc.identifier.other | sigarra:727083 | |
| dc.identifier.uri | https://hdl.handle.net/10216/166973 | - |
| dc.description | O parto pré-termo (PPT) tem um grande impacto na morbilidade e mortalidade infantil, representando um importante problema de saúde pública. Deste modo, é essencial a avaliação de risco de PPT para que o tratamento preventivo possa ser efetuado. Neste contexto, a medição ecográfica transvaginal do comprimento do colo do útero tem sido proposta e utilizada como um método eficaz de rastreio de PPT. Objetivo: Avaliar a eficácia e aplicabilidade da medição ecográfica transvaginal do comprimento do colo do útero na previsão de PPT em grávidas portuguesas, no segundo trimestre da gravidez. Métodos: Realizou-se um estudo observacional de coorte retrospetivo que incluiu todas as mulheres com gestação unifetal que realizaram a ecografia do segundo trimestre no Centro Hospitalar Universitário de São João, tiveram parto na mesma instituição e cuja medição ecográfica transvaginal do comprimento do colo do útero foi realizada de acordo com as normas da Fetal Medicine Foundation. Resultados: Foram incluídas 6433 mulheres na nossa coorte. O PPT espontâneo ocorreu em 3.5% dos casos, sendo 0.7% classificados como PPT precoce (<34 semanas de gestação). A média do comprimento do colo do útero na medição ecográfica transvaginal foi de 34.03mm ± 4.78 mm. A sensibilidade de um comprimento cervical inferior ou igual a 25mm foi de 9.3%, especificidade de 97.6%, área sob a curva de 0.53, valor preditivo negativo de 96.7% e valor preditivo positivo de 12.5%. Uma associação negativa entre comprimento do colo do útero e PPT foi demonstrada na análise de regressão logística múltipla, com um odds ratio de 0.91 (intervalo de confiança a 95% [IC95%]: 0,89-0,94; p < 0,001). Para a nossa coorte, o melhor ponto de corte de comprimento cervical demonstrado foi de 20mm. Conclusão: O nosso estudo confirmou que a medição ecográfica transvaginal do comprimento do colo do útero é uma ferramenta valiosa, especialmente na identificação de mulheres com baixo risco de PPT. No entanto, destaca-se a necessidade de um modelo de avaliação de risco integrado, de forma a melhorar o algoritmo de rastreio. Adicionalmente, salienta-se a importância da adoção de pontos de corte específicos para cada população, com o objetivo de melhorar a estratificação de risco. | |
| dc.description.abstract | Preterm birth (PTB) is a major public health problem with a big impact on infantile morbidity and mortality. Therefore, PTB risk assessment is essential so that treatment can be taken out as a preventive measure. Transvaginal ultrasound measurement of the cervical length (TUCL) has been proposed and adopted as an effective method for PTB screening. Purpose: To assess the second-trimester TUCL applicability and effectiveness in predicting PTB among Portuguese pregnant women. Methods: An observational retrospective cohort study was conducted including all singleton pregnant women who presented for second-trimester ultrasound at Centro Hospitalar Universitário de São João, delivered at the same institution and had TUCL according to the Fetal Medicine Foundation guidelines. Results: 6433 women were included in our cohort. Spontaneous PTB accounted for 3.5%, with 0.7% classified as early PTB (<34th week of gestation). The mean TUCL was 34.03mm ± 4.78mm. TUCL ≤25mm sensitivity was 9.3%, specificity 97.6%, area under the curve 0.53, negative predictive value 96.7% and positive predictive value 12.5%. A negative association between TUCL and PTB was showed in the multiple logistic regression analysis, with an odds ratio (OR) of 0.91 (95% confidence interval [95%CI]: 0.89-0.94; p<0.001). For our cohort, the best TUCL cut-off was 20mm. Conclusion: Our study confirmed that TUCL is a valuable tool, especially in identifying women with low-risk PTB. However, an integrative risk assessment model should be performed to improve the screening algorithm. Additionally, for risk stratification improvement, it highlights the importance of adopting population-specific cut-offs. | |
| dc.language.iso | eng | |
| dc.rights | restrictedAccess | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Medicina clínica | |
| dc.subject | Clinical medicine | |
| dc.title | Prediction of preterm birth: the accuracy of transvaginal cervical length measurement in the second trimester ultrasound | |
| dc.type | Dissertação | |
| dc.contributor.uporto | Faculdade de Medicina | |
| dc.identifier.doi | 10.34626/jsqf-er62 | |
| dc.identifier.tid | 204144370 | |
| dc.subject.fos | Ciências médicas e da saúde::Medicina clínica | |
| dc.subject.fos | Medical and Health sciences::Clinical medicine | |
| thesis.degree.discipline | Mestrado Integrado em Medicina | |
| thesis.degree.grantor | Faculdade de Medicina | |
| thesis.degree.grantor | Universidade do Porto | |
| thesis.degree.level | 1 | |
| Aparece nas coleções: | FMUP - Dissertação | |
Ficheiros deste registo:
| Ficheiro | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| 727083.pdf Restricted Access | Prediction of preterm birth: the accuracy of transvaginal cervical length measurement in the second trimester ultrasound | 7.06 MB | Adobe PDF | Ver/Abrir |
Este registo está protegido por Licença Creative Commons