Utilize este identificador para referenciar este registo: https://hdl.handle.net/10216/166973
Registo completo
Campo DCValorIdioma
dc.creatorMaria Lopes Teixeira de Sousa Oliveira
dc.date.accessioned2026-01-26T05:14:54Z-
dc.date.available2026-01-26T05:14:54Z-
dc.date.issued2025-05-13
dc.date.submitted2025-03-21
dc.identifier.othersigarra:727083
dc.identifier.urihttps://hdl.handle.net/10216/166973-
dc.descriptionO parto pré-termo (PPT) tem um grande impacto na morbilidade e mortalidade infantil, representando um importante problema de saúde pública. Deste modo, é essencial a avaliação de risco de PPT para que o tratamento preventivo possa ser efetuado. Neste contexto, a medição ecográfica transvaginal do comprimento do colo do útero tem sido proposta e utilizada como um método eficaz de rastreio de PPT. Objetivo: Avaliar a eficácia e aplicabilidade da medição ecográfica transvaginal do comprimento do colo do útero na previsão de PPT em grávidas portuguesas, no segundo trimestre da gravidez. Métodos: Realizou-se um estudo observacional de coorte retrospetivo que incluiu todas as mulheres com gestação unifetal que realizaram a ecografia do segundo trimestre no Centro Hospitalar Universitário de São João, tiveram parto na mesma instituição e cuja medição ecográfica transvaginal do comprimento do colo do útero foi realizada de acordo com as normas da Fetal Medicine Foundation. Resultados: Foram incluídas 6433 mulheres na nossa coorte. O PPT espontâneo ocorreu em 3.5% dos casos, sendo 0.7% classificados como PPT precoce (<34 semanas de gestação). A média do comprimento do colo do útero na medição ecográfica transvaginal foi de 34.03mm ± 4.78 mm. A sensibilidade de um comprimento cervical inferior ou igual a 25mm foi de 9.3%, especificidade de 97.6%, área sob a curva de 0.53, valor preditivo negativo de 96.7% e valor preditivo positivo de 12.5%. Uma associação negativa entre comprimento do colo do útero e PPT foi demonstrada na análise de regressão logística múltipla, com um odds ratio de 0.91 (intervalo de confiança a 95% [IC95%]: 0,89-0,94; p < 0,001). Para a nossa coorte, o melhor ponto de corte de comprimento cervical demonstrado foi de 20mm. Conclusão: O nosso estudo confirmou que a medição ecográfica transvaginal do comprimento do colo do útero é uma ferramenta valiosa, especialmente na identificação de mulheres com baixo risco de PPT. No entanto, destaca-se a necessidade de um modelo de avaliação de risco integrado, de forma a melhorar o algoritmo de rastreio. Adicionalmente, salienta-se a importância da adoção de pontos de corte específicos para cada população, com o objetivo de melhorar a estratificação de risco.
dc.description.abstractPreterm birth (PTB) is a major public health problem with a big impact on infantile morbidity and mortality. Therefore, PTB risk assessment is essential so that treatment can be taken out as a preventive measure. Transvaginal ultrasound measurement of the cervical length (TUCL) has been proposed and adopted as an effective method for PTB screening. Purpose: To assess the second-trimester TUCL applicability and effectiveness in predicting PTB among Portuguese pregnant women. Methods: An observational retrospective cohort study was conducted including all singleton pregnant women who presented for second-trimester ultrasound at Centro Hospitalar Universitário de São João, delivered at the same institution and had TUCL according to the Fetal Medicine Foundation guidelines. Results: 6433 women were included in our cohort. Spontaneous PTB accounted for 3.5%, with 0.7% classified as early PTB (<34th week of gestation). The mean TUCL was 34.03mm ± 4.78mm. TUCL ≤25mm sensitivity was 9.3%, specificity 97.6%, area under the curve 0.53, negative predictive value 96.7% and positive predictive value 12.5%. A negative association between TUCL and PTB was showed in the multiple logistic regression analysis, with an odds ratio (OR) of 0.91 (95% confidence interval [95%CI]: 0.89-0.94; p<0.001). For our cohort, the best TUCL cut-off was 20mm. Conclusion: Our study confirmed that TUCL is a valuable tool, especially in identifying women with low-risk PTB. However, an integrative risk assessment model should be performed to improve the screening algorithm. Additionally, for risk stratification improvement, it highlights the importance of adopting population-specific cut-offs.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectMedicina clínica
dc.subjectClinical medicine
dc.titlePrediction of preterm birth: the accuracy of transvaginal cervical length measurement in the second trimester ultrasound
dc.typeDissertação
dc.contributor.uportoFaculdade de Medicina
dc.identifier.doi10.34626/jsqf-er62
dc.identifier.tid204144370
dc.subject.fosCiências médicas e da saúde::Medicina clínica
dc.subject.fosMedical and Health sciences::Clinical medicine
thesis.degree.disciplineMestrado Integrado em Medicina
thesis.degree.grantorFaculdade de Medicina
thesis.degree.grantorUniversidade do Porto
thesis.degree.level1
Aparece nas coleções:FMUP - Dissertação

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
727083.pdf
  Restricted Access
Prediction of preterm birth: the accuracy of transvaginal cervical length measurement in the second trimester ultrasound7.06 MBAdobe PDFVer/Abrir


Este registo está protegido por Licença Creative Commons Creative Commons