Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/159452
Full metadata record
DC FieldValueLanguage
dc.creatorSantos, Tânia
dc.creatorGuerra, R.S.
dc.creatorValdiviesso, Rui
dc.creatorAmaral, Teresa
dc.date.accessioned2024-12-07T00:17:58Z-
dc.date.available2024-12-07T00:17:58Z-
dc.date.issued2024
dc.identifier.issn2072-6643
dc.identifier.othersigarra:678622
dc.identifier.urihttps://hdl.handle.net/10216/159452-
dc.description.abstractBackground: Handgrip strength (HGS) is an indicator of muscular strength, used in the diagnosis of sarcopenia, undernutrition, and physical frailty as well as recovery. Typically, the maximum HGS value is used; however, recent evidence suggests the exploration of new indicators provided based on the force-time curve to achieve a more comprehensive assessment of muscle function. Therefore, the objective was to identify indicators of the HGS profile beyond maximum HGS, based on force-time curves, and to systematize knowledge about their applications to various types of samples, health issues, and physical performance. Methods: A systematic review was performed including studies whose participants' HGS was assessed with a digital or adapted dynamometer. The outcome measures were HGS profile indicators calculated from the force-time curve. Results: a total of 15 studies were included, and the following indicators were identified: grip fatigue, fatigability index, fatigue rate, fatigue resistance, time to 80% maximal voluntary contraction, plateau coefficient of variability, time to maximum value, T-90%, release rate, power factor, grip work, average integrated area, endurance, cycle duration, time between cycles, maximum and minimum force-velocity, rate of grip force, final force, inflection point, integrated area, submaximal control, and response time. Conclusions: Various indicators based on the force-time curve can be assessed through digital or adapted dynamometers. Future research should analyze these indicators to understand their implications for muscle function assessment, to standardize evaluation procedures, to identify clinically relevant measures, and to clarify their implications in clinical practice.
dc.language.isoeng
dc.rightsopenAccess
dc.subjectCiências da Saúde, Ciências médicas e da saúde
dc.subjectHealth sciences, Medical and Health sciences
dc.titleHand Grip Force-Time Curve Indicators Evaluated by Dynamometer: A Systematic Review
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Ciências da Nutrição e Alimentação
dc.identifier.doi10.3390/nu16121951
dc.identifier.authenticusP-010-P8S
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Appears in Collections:FCNAUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
678622.pdf22.95 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.