dc.descriptionIntrodução: A incorporação da frequência cardíaca materna na análise da frequência cardíaca fetal antecipa hipoxemia fetal, acidose e distocia, melhorando a monitorização da frequência cardíaca fetal. No entanto, a avaliação da performance de técnicas de aquisição da frequência cardíaca materna no período intraparto continua indevidamente esclarecida. O objetivo deste estudo será a comparação da frequência cardíaca materna obtida simultaneamente via eletrocardiografia e fotopletismografia no período intraparto. Métodos: Foram obtidos cinquenta e dois traçados de frequência cardíaca materna via eletrocardiografia e via fotopletismografia simultaneamente, de cinquenta e duas mulheres em trabalho de parto, nas últimas duas horas deste período (H1 e H2), sendo que cada traçado analisado ocorreu durante > 110 minutos. As diferenças, a correlação e a discordância entre estes foram analisadas através do teste de Wilcoxon, o coeficiente de correlação de Spearman e a medida não paramétrica de discordância dAB, respetivamente. Foram avaliados os seguintes parâmetros: baseline, número de acelerações, número de desacelerações, short-term variability média e anormal e long-term variability média e anormal. Resultados: A baseline obtida através de fotopletismografia demonstrou uma forte correlação com a obtida por eletrocardiografia. O número de acelerações, short e long term varibiability médias foram significativamente inferiores por fotopletismografia, porém com boa correlação. Short e long term variability anormais foram significativamente superiores com fotopletismografia, com uma correlação mais baixa e uma discordância maior. Discussão: As técnicas de aquisição de frequência cardíaca por eletrocardiografia bem como por fotopletismografia podem levar a disparidades de sinal obtido. A eletrocardiografia apresenta uma maior resolução de sinal enquanto, através da fotopletismografia se obtém um short-term variability médio estatisticamente inferior, originando um short-term variability anormal superior. Uma vez que não há evidência conclusiva que demonstre que a eletrocardiografia apresenta uma capacidade diagnóstica superior, sistemas de análise automatizada como o Omniview-SisPorto devem adaptar as suas regras de decisão de acordo com o método escolhido.
dc.description.abstractBackground: Electronic fetal heart rate monitoring incorporating maternal heart rate (MHR) analysis may better anticipate fetal hypoxia, acidosis and labour dystocia, improving fetal surveillance. However, the performance of available MHR acquisition techniques during labour remains inadequately evaluated. The aim of this study was to compare intrapartum MHR simultaneously acquired by electrocardiography (ECG) and photoplethysmography (PPG). Methods: Fifty-two MHR recordings were simultaneously obtained by ECG and PPG, corresponding to the same number of women in labour, during the final two hours of labour (H1 and H2), each recording lasting >110 minutes. Differences, correlation and disagreement between ECG and PPG signals were, respectively, assessed using the Wilcoxon test, the Spearman correlation coefficient and the nonparametric measure of disagreement dAB. The following variables were evaluated: baseline, number of accelerations, number of decelerations, average and abnormal short-term variability, average and abnormal long-term variability. Results: Baseline obtained through PPG signal presented a strong correlation with ECG. The number of accelerations, average short- and long-term variability were significantly lower with PPG but with a good correlation. Abnormal short- and long-term variability were significantly higher with PPG, with lower correlation and higher disagreement. Discussion: Heart rate acquisition techniques from both ECG and PPG may yield signal disparities. ECG signals offer higher resolution, while PPG exhibits significantly lower average short-term variability, leading to elevated abnormal short-term variability. As no conclusive evidence has established ECG superiority in diagnostic capacity, computerized systems like Omniview-SisPorto should adapt their decision rules according to the chosen method.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectMedicina clínica
dc.subjectClinical medicine
dc.titleComputerized analysis of the maternal heart rate during labour using the Omniview-SisPorto system: electrocardiography versus photoplethysmography
dc.typeDissertação
dc.contributor.uportoFaculdade de Medicina
dc.identifier.doi10.34626/7ssg-7007
dc.identifier.tid203752554
dc.subject.fosCiências médicas e da saúde::Medicina clínica
dc.subject.fosMedical and Health sciences::Clinical medicine
thesis.degree.disciplineMestrado Integrado em Medicina
thesis.degree.grantorFaculdade de Medicina
thesis.degree.grantorUniversidade do Porto
thesis.degree.level1
Appears in Collections:FMUP - Dissertação

Files in This Item:
File Description SizeFormat 
674444.pdf
  Restricted Access
Computerized analysis of the maternal heart rate during labour using the Omniview-SisPorto system: electrocardiography versus photoplethysmography1.28 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons