Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/150277
Full metadata record
DC FieldValueLanguage
dc.creatorJosé Rui de Oliveiros Vicetro Abrantes Saraiva
dc.date.accessioned2025-11-12T06:03:56Z-
dc.date.available2025-11-12T06:03:56Z-
dc.date.issued2023-05-18
dc.date.submitted2023-03-24
dc.identifier.othersigarra:630521
dc.identifier.urihttps://hdl.handle.net/10216/150277-
dc.descriptionObjetivos: Avaliar e combinar, através de uma revisão sistemática e meta-análise, os resultados clínicos e hemodinâmicos a curto e longo prazo, após da substituição da válvula aórtica(SVA) com as biopróteses Freedom SOLO ou SOLO SMART. Métodos: Foi realizada uma revisão de literatura, utilizando 3 databases e os artigos que reportaram pelo menos um dos seguintes resultados: mortalidade, complicações imediatas, necessidade de reoperação ou avaliação hemodinâmica, foram incluídos. Utilizaram-se modelos de efeitos aleatórios para calcular as estimativas combinadas (modelo linear generalizados de efeitos mistos e logit para proporções e método de variância inversa para as variáveis contínuas). Resultados: De 355 registros selecionados, 110 estudos foram selecionados para avaliação de elegibilidade. Destes, 45 estudos foram incluídos nesta meta-análise, publicados entre 2006 e 2021. Do total de 7.869 pacientes,48% eram do dexo masculino(intervalo de confiança (IC) de 95%: 45-53%, I2: 78,8%) e a idade média agrupada foi de 74 anos (IC 95%: 73-75), I2: 87,4%. A medida agrupada do Euroscore logístico foi de 11,5 (IC 95%: 8,7-14,3). A mortalidade a curto prazo ocorreu em 3,1% (IC95%: 2,6-3,6) dos pacientes, problemas hemorrágicos em 4,1% (IC95%: 2,6- 6,3) e eventos neurológicos em 2,1% (IC 95%: 1,7-2,7). O implante de pacemaker definitivo foi necessário em 1,9% (IC95%: 1,5-2,5). O tempo de seguimento variou de 5 dias a 10 anos. A sobrevivência cumulativa aos 1, 3 e 5 anos variaram entre 87,5% e 97,0%, 82,6% e 96,0% e 58,5% e 94 ,0%, respetivamente. Conclusão: A substituição da valva aórtica com a FS pode ser considerada um procedimento seguro, considerando os resultados satisfatórios revelados a curto e médio prazo.
dc.description.abstractIntroduction: Almost 20 years after the introduction of the Freedom Solo stentless bioprosthesis, it is of utmost relevance to systemize the available evidence on its clinical and hemodynamic outcomes. Objectives: To describe and combine, through a systematic review and meta-analysis, early and long-term outcomes after aortic valve replacement (AVR) with the Freedom Solo or Solo SMART Stentless(FS) bioprostheses. Evidence acquisition: A literature review was performed using 3 databases. Studies that reported at least one of the following outcomes: mortality, immediate complications, need for reoperation or hemodynamic evaluation, were included. Random effects models were used to compute pooled estimates by generalized linear mixed-effects model and logit-transformed for proportions and by inverse variance method for continuous variables. Evidence synthesis: From 355 records screened, 110 studies were selected for eligibility assessment. Out of these, 45 studies were included in this meta-analysis. From a total of 7-869 patients, 48% were men, 95% confidence interval (CI): 45-53%, I2: 78.8% and the pooled mean age was 74 years (95%CI: 73-75), I2: 87.4%. The pooled mean logistic Euroscore was 11.5(95%CI: 8.7-14.3). Early mortality occurred in 3.1% (95%CI: 2.6-3.6) of patients, bleeding problems in 4.1% (95%CI: 2.6-6.3) and neurological events in 2.1% (95%CI: 1.7-2.7). Definitive pacemaker implantation was needed in 1.9% (95%CI: 1.5-2.5). The follow-up time ranged from 5 days to 10 years. Survival rates at 1-, 3- and 5-years ranged between 87.5% and 97.0%, 82.6% and 96.0%, and 58.5% and 94.0%, respectively. Conclusions: AVR with FS bioprosthesis can be considered a safe procedure, as supported by satisfactory early and mid-term outcomes.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectCiências médicas e da saúde
dc.subjectMedical and Health sciences
dc.titleFreedom and Smart Solo Stentless Bioprosthesis for Aortic Valve Replacement - clinical and hemodynamic evaluation-systematic review and meta-analysis
dc.typeDissertação
dc.contributor.uportoFaculdade de Medicina
dc.identifier.doi10.34626/81fb-qz56
dc.identifier.tid203521951
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
thesis.degree.disciplineMestrado Integrado em Medicina
thesis.degree.grantorFaculdade de Medicina
thesis.degree.grantorUniversidade do Porto
thesis.degree.level1
Appears in Collections:FMUP - Dissertação

Files in This Item:
File Description SizeFormat 
630521.pdf
  Restricted Access
Solo Stentless Bioprosthesis for Aortic Valve Replacement - clinical and hemodynamic evaluation-systematic review and meta-analysis5.83 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons