Utilize este identificador para referenciar este registo: https://hdl.handle.net/10216/144347
Registo completo
Campo DCValorIdioma
dc.creatorSilva, T.
dc.creatorNunes, CL
dc.creatorJesus, F
dc.creatorFrancisco, R
dc.creatorTeixeira, Vitor Hugo
dc.creatorSardinha, LB
dc.creatorMartins, P
dc.creatorMinderico, C
dc.creatorSilva, AM
dc.date.accessioned2023-01-21T00:28:14Z-
dc.date.available2023-01-21T00:28:14Z-
dc.date.issued2022
dc.identifier.issn0264-0414
dc.identifier.othersigarra:585490
dc.identifier.urihttps://hdl.handle.net/10216/144347-
dc.description.abstractIt is unclear if different bioelectrical impedance (BI) devices provide similar results regarding raw parameters [Resistance (R), Reactance (Xc), Phase Angle (PhA), and Impedance (Z)] for the same population/individual undergoing a weight loss intervention. The aim was to evaluate the cross-sectional and longitudinal agreement of raw data obtained by two BI devices in former athletes with overweight/obesity. Fifty-nine participants [mean (SD): 43.5 (9.2) years, 30.5 (4.0) kg/m(2), 42% females] were included. All the assessments were performed before and after a 4-months lifestyle intervention targeting weight loss (WL). BI parameters were assessed at 50 kHz by two devices: a BI spectroscopy (Xitron Technologies, 4200B, San Diego, USA) and a phase-sensitive single-frequency device (RJL/Akern Systems, BIA-101, Italy). Cross-sectionally, BIS provided lower mean values for all parameters (0.4% for R, 1.6% for Xc, 1.0% for PhA and 0.4% for Z, p <0.001) compared to SF-BIA. In individuals with a WL >= 2.5% (n =18), no longitudinal differences were found in any of the raw parameters between devices (p >= 0.128) and there was no proportional bias (p >= 0.408). Despite small baseline differences in raw BI parameters, both devices agreed in tracking changes over time at the group level but interpretation should be careful at the individual level.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectCiências da Saúde, Ciências médicas e da saúde
dc.subjectHealth sciences, Medical and Health sciences
dc.titleBetween-devices agreement in obtaining raw bioelectrical parameters after a lifestyle intervention targeting weight loss in former athletes
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Ciências da Nutrição e Alimentação
dc.identifier.doi10.1080/02640414.2022.2115755
dc.identifier.authenticusP-00X-7Y3
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Aparece nas coleções:FCNAUP - Artigo em Revista Científica Internacional

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
585490.pdf
  Restricted Access
1.29 MBAdobe PDFVer/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.