Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/137527
Full metadata record
DC FieldValueLanguage
dc.creatorBernardo, F
dc.creatorMoreira, JL
dc.creatorGonçalves, C
dc.creatorPena, MJ
dc.creatorPinho, Olívia
dc.creatorMartins, R
dc.creatorAlves, A
dc.date.accessioned2022-09-08T10:49:58Z-
dc.date.available2022-09-08T10:49:58Z-
dc.date.issued2022
dc.identifier.issn0889-1575
dc.identifier.othersigarra:513285
dc.identifier.urihttps://hdl.handle.net/10216/137527-
dc.description.abstractExcessive salt intake is a growing concern in society, impacting on a number of serious clinical conditions, such as the development of hypertension and increased mortality/morbidity caused by cardiovascular diseases. The urgent need to introduce in situ assessment of the salt content of processed foods led to the development of SALTQUANTI, a portable device developed and patented by a consortium promoted by the company EVOLEO Technologies and the University of Porto, which combines sample preparation with the analytical detection by means of a sodium selective electrode with potentiometric detection. The device includes the milling and stirring process of the sample, together with the analytical measurement and data interpretation via a touch display. Data for the analytical validation of the method were obtained from 20 different processed food samples. The linearity of the method was in the range from 0.06 to 6.00 g salt/100 g food. The precision was of 6% on average, considering repeatability of results for different types of processed food and the accuracy was of 9% on average. Interlaboratorial comparison showed deviation of results of less than 20 % for the different types of samples. The analytical procedure proved to be simple and reliable, and automation enabled the analysis in less than 5 min with an acceptable uncertainty. (c) 2021
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectCiências da Saúde, Ciências médicas e da saúde
dc.subjectHealth sciences, Medical and Health sciences
dc.titleSaltquanti - development of a new portable device to analyse salt content in food
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Ciências da Nutrição e Alimentação
dc.identifier.doi10.1016/j.jfca.2021.104239
dc.identifier.authenticusP-00V-M3S
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Appears in Collections:FCNAUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
513285.pdf
  Restricted Access
1.4 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.