dc.creatorJuliana V. Teixeira
dc.creatorSandra Miranda
dc.creatorRicardo A. R. Monteiro
dc.creatorFilipe V. S. Lopes
dc.creatorJoana Madureira
dc.creatorGabriela V. Silva
dc.creatorNazaré Pestana
dc.creatorEugénia Pinto
dc.creatorVítor J. P. Vilar
dc.creatorRui A. R. Boaventura
dc.date.accessioned2022-09-09T04:42:43Z-
dc.date.available2022-09-09T04:42:43Z-
dc.date.issued2013
dc.identifier.issn0167-6369
dc.identifier.othersigarra:68853
dc.identifier.urihttps://hdl.handle.net/10216/105981-
dc.description.abstractThe main objective of this work was to quantify and characterize the major indoor air contaminants present in different stages of a municipal WWTP, including microorganisms (bacteria and fungi), carbon dioxide, carbon monoxide, hydrogen sulfide ammonia, formaldehyde, and volatile organic compounds (VOCs). In general, the total bacteria concentration was found to vary from 60 to > 52,560 colony-forming units (CFU)/m(3), and the total fungi concentration ranged from 369 to 14,068 CFU/m(3). Generally, Gram-positive bacteria were observed in higher number than Gram-negative bacteria. CO2 concentration ranged from 251 to 9,710 ppm, and CO concentration was either not detected or presented a level of 1 ppm. H2S concentration ranged from 0.1 to 6.0 ppm. NH3 concentration was < 2 ppm in most samples. Formaldehyde was < 0.01 ppm at all sampling sites. The total VOC concentration ranged from 36 to 1,724 mu g/m(3). Among the VOCs, toluene presented the highest concentration. Results point to indoor/outdoor ratios higher than one. In general, the highest levels of airborne contaminants were detected at the primary treatment (SEDIPAC 3D), secondary sedimentation, and sludge dehydration. At most sampling sites, the concentrations of airborne contaminants were below the occupational exposure limits (OELs) for all the campaigns. However, a few contaminants were above OELs in some sampling sites.
dc.language.isoeng
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Programa de Financiamento Plurianual de Unidades de I&D/PEst-C/EQB/LA0020/2011/Projeto Estratégico-LA 20 - 2011-2012/LA 20
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Projectos de I&DT em Todos os Domínios Científicos/PTDC/EQU-EQU/100554/2008/AIRPHOTOXI-DESTOXIFICAÇÃO SOLAR DE AR INTERIOR: BIOAEROSSÓIS E COVs/AIRPHOTOXI
dc.rightsrestrictedAccess
dc.subjectCiências Tecnológicas, Ciências da terra e ciências do ambiente
dc.subjectTechnological sciences, Earth and related Environmental sciences
dc.titleAssessment of indoor airborne contamination in a wastewater treatment plant
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.contributor.uportoFaculdade de Farmácia
dc.contributor.uportoFaculdade de Ciências
dc.identifier.doi10.1007/s10661-012-2533-0
dc.identifier.authenticusP-002-1Z2
dc.subject.fosCiências exactas e naturais::Ciências da terra e ciências do ambiente
dc.subject.fosNatural sciences::Earth and related Environmental sciences
Aparece nas coleções:FCUP - Artigo em Revista Científica Internacional
FEUP - Artigo em Revista Científica Internacional
FFUP - Artigo em Revista Científica Internacional

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
68853.pdf
  Restricted Access
424.49 kBAdobe PDFVer/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.