Please use this identifier to cite or link to this item:
https://hdl.handle.net/10216/94922| Author(s): | N. M. RAMOS V. P. de FREITAS |
| Title: | Laboratory testing for daily hygroscopic inertia assessment |
| Issue Date: | 2008 |
| Abstract: | This article describes an extensive experimental campaign aiming at the characterization of the moisture buffering capacity of interior finishing system and the assessment of the hygroscopic inertia of a room. The MBV - Moisture Buffer Value is evaluated for gypsum based products finished with different coatings. The assessment of hygroscopic inertia at room level is implemented using a flux chamber designed specifically for this experiment. A daily hygroscopic inertia index, Ih,d, is defined using MBV as a basis for the assessment of materials contribution to the buffering capacity of a room. The correlation between that index and peak dampening is proved using the presented experimental results. |
| Subject: | Engenharia civil, Outras ciências da engenharia e tecnologias Civil engineering, Other engineering and technologies |
| Scientific areas: | Ciências da engenharia e tecnologias::Outras ciências da engenharia e tecnologias Engineering and technology::Other engineering and technologies |
| URI: | https://hdl.handle.net/10216/94922 |
| Source: | Proceedings of the 8th Symposium on Building Physics in the Nordic Countries |
| Document Type: | Artigo em Livro de Atas de Conferência Internacional |
| Rights: | restrictedAccess |
| Appears in Collections: | FEUP - Artigo em Livro de Atas de Conferência Internacional |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 62125.pdf Restricted Access | Laboratory testing for daily hygroscopic inertia assessment | 367.01 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.