Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/23218
Author(s): António P. O. Carvalho
Pedro M. A. Silva
Title: Sound, noise and speech at the 9000-seat Holy Trinity Church in Fatima, Portugal
Issue Date: 2010
Abstract: This paper presents the interior acoustical characterization of the 9,000-seat church of the Holy Trinity in the Sanctuary of Fátima, Portugal, inaugurated in 2007. In situ measurements were held regarding interior sound pressure levels (with and without the HVAC equipment working), NC curves, RASTI (with and without the installed sound system) and reverberation time. The results are presented and commented according to the design values. A comparison is made with other churches in the world also with a very large volume (for instance the Basilica Mariacka in Gdask). The measured data are also used to calculate a global index of this church acoustic quality using Engel and Kosalas Index Method.
Subject: Acústica, Engenharia civil
Acoustics, Civil engineering
Scientific areas: Ciências da engenharia e tecnologias::Engenharia civil
Engineering and technology::Civil engineering
DOI: 10.2478/v10168-010-0013-5
URI: https://hdl.handle.net/10216/23218
Source: Noise Control '10
Document Type: Artigo em Livro de Atas de Conferência Internacional
Rights: openAccess
License: https://creativecommons.org/licenses/by-nc/4.0/
Appears in Collections:FEUP - Artigo em Livro de Atas de Conferência Internacional

Files in This Item:
File Description SizeFormat 
60970.pdfPaper1.75 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons