Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/165981
Full metadata record
DC FieldValueLanguage
dc.creatorKlara Slezakova
dc.creatorEsteves F.
dc.creatorVaz J
dc.creatorCosta S.
dc.creatorAlves M.J.
dc.creatorMadureira J.
dc.creatorBarros B.
dc.creatorFernandes A.
dc.creatorTeixeira J.P.
dc.creatorMorais S.
dc.creatorMaria do Carmo Pereira
dc.date.accessioned2025-03-30T00:07:16Z-
dc.date.available2025-03-30T00:07:16Z-
dc.date.issued2024
dc.identifier.othersigarra:667383
dc.identifier.urihttps://hdl.handle.net/10216/165981-
dc.description.abstractThis work assessed firefighters exposure to gases pollutants in non- fire work settings during the pre-fire season as a baseline for the respective occupational exposure characterization. Indoor air sampling (total volatile organic compoundsTVOCs, ozone-O3, and carbon di oxide-CO2) was conducted for two weeks in the pre-fire season of 2021 in seven firehouses (FH1FH7) situated in the north-interior of Portugal. The result showed that across all FH, TVOCs highly varied with observed levels of 180 g m3 and 11.5 mg m3 (overall median of 1.86 mg m3). Furthermore, at all FH, the observed levels highly exceeded (1.56.6 times) the Portuguese protective thresholds of 600 g m3 for indoor air quality in public buildings. On the contrary, the indoor ozone concentrations (range: 2380 g m3; median 60 g m3) and CO2 (range 8001160 mg m-3: median 924 mg m3) were relatively low and in accordance with existing national standards. While the associations between the pollutants were lowmoderate (|rs|= 0.0300.679) to better identify the respective indoor emission sources, quantification of specific VOC compounds/classes is required in future studies. (c) The Author(s), under exclusive license to Springer Nature Switzerland AG 2024.
dc.language.isoeng
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Programa de Financiamento Plurianual de Unidades de I&D/UIDB/00511/2020_UIDP/00511/2020/Financiamento Plurianual 2020-2023 da Unidade de I&D LEPABE - Laboratório de Engenharia de Processos, Ambiente, Biotecnologia e Energia/LEPABE
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Programa de Financiamento Plurianual de Unidades de I&D/LA/P/0045/2020/ALiCE - Laboratório Associado em Engenharia Química/ALiCE
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Prevenção e Combate a Incêndios Florestais/PCIF/SSO/0017/2018/Um painel de (bio)marcadores para a vigilância da saúde e da segurança do bombeiro/BioFirEx
dc.relation.ispartofStudies in Systems, Decision and Control
dc.rightsrestrictedAccess
dc.subjectCiências do ambiente
dc.subjectEnvironmental science
dc.titleIndoor Air Quality at Portuguese Firehouses
dc.typeCapítulo ou Parte de Livro
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1007/978-3-031-38277-2_35
dc.identifier.authenticusP-00Z-EXH
Appears in Collections:FEUP - Capítulo ou Parte de Livro

Files in This Item:
File Description SizeFormat 
667383.pdf
  Restricted Access
4.86 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.