Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/148145
Full metadata record
DC FieldValueLanguage
dc.creatorTeixeira, SFCF
dc.creatorRodrigues, NNJO
dc.creatorAlberto Miguel
dc.creatorOliveira, RF
dc.creatorTeixeira, JCF
dc.creatorJoão Santos Baptista
dc.date.accessioned2023-03-02T00:09:10Z-
dc.date.available2023-03-02T00:09:10Z-
dc.date.issued2014
dc.identifier.othersigarra:140264
dc.identifier.urihttps://hdl.handle.net/10216/148145-
dc.description.abstractComfort is important in everybody's lives, as it is not only a health subject, but also a productive issue. As environmental conditions differ accordingly to the space use, there is a direct influence of this space on human comfort. The Heating Ventilation and Air Conditioning (HVAC) Systems are a crucial way to obtain the expected air quality levels in the interior of buildings and to achieve thermal comfort. These systems ensure air renewal, pressurization, temperature control, and air humidity, being of utmost importance in healthcare facilities. Providing thermal comfort conditions and good air quality, especially in operating rooms, is a difficult task, as the environmental conditions should be suitable for medical staff performance and for patient safety, as well. In the current study, a Computational Fluid Dynamics model was developed and coupled with a thermoregulatory model of the human body to describe the fluid flow, heat transfer and mass transfer between the ventilation air and a human manikin inside an operating room. The CFD simulation solves the heat, mass and momentum conservation equations in the computation domain using a finite volume discretization method, in the ANSYS - environment. The interaction between the body and the environment is determined by the thermoregulatory model, which includes temperature and the moisture diffusion through the cloth fabrics. The combination of the human body and space ventilation models allows evaluating the influence of the main thermal comfort variables on the calculation of comfort index, such as, the PMV.
dc.language.isoeng
dc.relation.ispartofProceedings of the 15th International Heat Transfer Conference, IHTC 2014
dc.rightsopenAccess
dc.titleModeling the thermal environment in an operating room
dc.typeArtigo em Livro de Atas de Conferência Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1615/ihtc15.cnv.009593
dc.identifier.authenticusP-00K-EP4
Appears in Collections:FEUP - Artigo em Livro de Atas de Conferência Internacional

Files in This Item:
File Description SizeFormat 
140264.pdf1.39 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.