dc.description.abstractThroughout the last years, the study of the masonry infill walls out-of-plane behavior is being observed by the scientific community with special attention, mainly due to damages observed during post-earthquake scenarios, where several number of damages and out-of-plane collapses of infill panels were found. Different causes are pointed to justify the seismic vulnerability of these type of elements, most of all related to deficient construction practices, which are nowadays still applicable Based on this motivation, two experimental quasi-static, full-scale, out-ofplane tests were carried out on RC frames that were built and infilled with a thin masonry wall made up of horizontal hollow clay bricks. The first specimen is representative of the enclosure of a typical existing RC building in the Southern countries in its "as-built" condition. The second specimen was strengthened with textile-reinforced mortar using glass fiber mesh. Both specimens were subjected to semi-cyclic (loading-unloading-reloading) history of imposed displacements by means of small pneumatic jacks through a uniform distributed load. Experimental results will be presented and detailed in terms of out-of-plane force-displacement responses and damage evolution. In the end, the results of the tests are compared to assess the effectiveness of the strengthening technique.
dc.language.isoeng
dc.relation.ispartof7th ECCOMAS International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering (COMPDYN 2019)
dc.rightsopenAccess
dc.subjectEngenharia estrutural, Engenharia civil
dc.subjectStructural engineering, Civil engineering
dc.titleExperimental assessment of strengthening strategy to improve the masonry infills out-of-plane behaviour through textile reinforced mortar
dc.typeArtigo em Livro de Atas de Conferência Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.authenticusP-012-GJR
dc.subject.fosCiências da engenharia e tecnologias::Engenharia civil
dc.subject.fosEngineering and technology::Civil engineering
Aparece nas coleções:FEUP - Artigo em Livro de Atas de Conferência Internacional

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
416657.pdfEXPERIMENTAL ASSESSMENT OF STRENGTHENING STRATEGY TO IMPROVE THE MASONRY INFILLS OUT-OF-PLANE BEHAVIOUR THROUGH TEXTILE REINFORCED MORTAR1.04 MBAdobe PDFThumbnail
Ver/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.