Utilize este identificador para referenciar este registo: https://hdl.handle.net/10216/125239
Registo completo
Campo DCValorIdioma
dc.creatorRicardo Fitas
dc.creatorCatarina Castro
dc.creatorLuísa Costa Sousa
dc.creatorCarlos Alberto Conceição António
dc.creatorSantos, R
dc.creatorElsa Azevedo
dc.date.accessioned2022-09-07T21:14:27Z-
dc.date.available2022-09-07T21:14:27Z-
dc.date.issued2019
dc.identifier.othersigarra:374111
dc.identifier.urihttps://hdl.handle.net/10216/125239-
dc.description.abstractThe study presented here addresses segmentation methodologies applied to Doppler ultrasound images of the carotid bifurcation acquired as a sequence of 2D ultrasound transverse images. Initial identification of image elements representing transversal cuts of the artery followed by parameter analysis enables a fast methodology for lumen and artery wall identification and segmentation for the complete image sequence. Different arterial geometries, along with the presence of plaque, artefacts and speckle noise, can modify the expected circular shapes of the arteries making identification extremely difficult. Initial identified parameters are crucial for the analysis of image behavior across the bifurcation suggesting methodologies for image correction and irregularity detection on the artery representation. Statistical analysis of the accuracy of the bifurcation modelling from transverse image segmentation validates the methodology results as compared to results from medical manual segmentation and results from segmentation of longitudinal Doppler ultrasound images. (c) Springer Nature Switzerland AG 2019.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectEngenharia, Ciências da Saúde, Ciências da engenharia e tecnologias, Ciências médicas e da saúde
dc.subjectEngineering, Health sciences, Engineering and technology, Medical and Health sciences
dc.titleAnalysis of Sequential Transverse B-Mode Ultrasound Images of the Carotid Artery Bifurcation
dc.typeCapítulo ou Parte de Livro
dc.contributor.uportoFaculdade de Engenharia
dc.contributor.uportoFaculdade de Medicina
dc.identifier.doi10.1007/978-3-030-32040-9_53
dc.identifier.authenticusP-00R-593
dc.subject.fosCiências da engenharia e tecnologias
dc.subject.fosEngineering and technology
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Aparece nas coleções:FEUP - Capítulo ou Parte de Livro
FMUP - Capítulo ou Parte de Livro

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
374111.pdf
  Restricted Access
Artigo completo351.48 kBAdobe PDFVer/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.