Utilize este identificador para referenciar este registo: https://hdl.handle.net/10216/108251
Autor(es): Pedro Morais
João Manuel R. S. Tavares
Sandro Queirós
Fernando Veloso
Jan D'hooge
João L. Vilaça
Título: Development of a patient-specific atrial phantom model for planning and training of inter-atrial interventions
Data de publicação: 2017-11
Resumo: Background: Several authors have presented cardiac phantoms to mimic the particularities of the heart, making it suitable for medical training and surgical planning. Although the initial models were mainly focused on the ventricles, personalized phantoms of the atria were recently presented. However, such models are typically rigid, the atrial wall is not realistic and it is not compatible with ultrasound, being sub-optimal for planning/training of several interventions. Methods: In this work, we propose a strategy to construct a patient-specific atrial model. Specifically, the target anatomy is generated using a computed tomography (CT) dataset and then constructed using a mold-cast approach. An accurate representation of the inter-atrial wall (IAS)was ensured during the model generation, allowing its application for IAS interventions. Two phantoms were constructed using different flexible materials (silicone and polyvinyl alcohol cryogel, PVA-C), which were then compared to assess their appropriateness for ultrasound (US) acquisition and for the generation of complex anatomies.Results: Two experiments were set up to validate the proposed methodology. First, the accuracy of the manufacturing approach was assessed through the comparison between a post-production CT and the virtual references. The results proved that the silicone-based model was more accurate than the PVA-C-based one, with an error of 1.68±0.79, 1.36±0.94, 1.45±0.77 mm for the left (LA) and right atria (RA) and IAS, respectively. Secondly, an US acquisition of each model was performed and the obtained images quantitatively and qualitatively assessed. Both models showed a similar performance in terms of visual evaluation, with an easy detection of the LA, RA and the IAS. Furthermore, a moderate accuracy was obtained between the atrial surfaces extracted from the US and the ideal reference, and again a superior performance of the silicone-based model against the PVA-C phantom was found.Conclusions: The proposed strategy proved
Assunto: Ciências Tecnológicas, Ciências médicas e da saúde
Technological sciences, Medical and Health sciences
Áreas do conhecimento: Ciências médicas e da saúde
Medical and Health sciences
DOI: 10.1002/mp.12559
URI: https://hdl.handle.net/10216/108251
Tipo de Documento: Artigo em Revista Científica Internacional
Condições de Acesso: openAccess
Aparece nas coleções:FEUP - Artigo em Revista Científica Internacional

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
225381.1.pdfPaper draft10.23 MBAdobe PDFThumbnail
Ver/Abrir
225381.png1st Page568.15 kBimage/pngThumbnail
Ver/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.