Please use this identifier to cite or link to this item:
https://hdl.handle.net/10216/108251
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Pedro Morais | |
dc.creator | João Manuel R. S. Tavares | |
dc.creator | Sandro Queirós | |
dc.creator | Fernando Veloso | |
dc.creator | Jan D'hooge | |
dc.creator | João L. Vilaça | |
dc.date.accessioned | 2019-11-26T00:12:01Z | - |
dc.date.available | 2019-11-26T00:12:01Z | - |
dc.date.issued | 2017-11 | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.other | sigarra:225381 | |
dc.identifier.uri | https://hdl.handle.net/10216/108251 | - |
dc.description.abstract | Background: Several authors have presented cardiac phantoms to mimic the particularities of the heart, making it suitable for medical training and surgical planning. Although the initial models were mainly focused on the ventricles, personalized phantoms of the atria were recently presented. However, such models are typically rigid, the atrial wall is not realistic and it is not compatible with ultrasound, being sub-optimal for planning/training of several interventions. Methods: In this work, we propose a strategy to construct a patient-specific atrial model. Specifically, the target anatomy is generated using a computed tomography (CT) dataset and then constructed using a mold-cast approach. An accurate representation of the inter-atrial wall (IAS)was ensured during the model generation, allowing its application for IAS interventions. Two phantoms were constructed using different flexible materials (silicone and polyvinyl alcohol cryogel, PVA-C), which were then compared to assess their appropriateness for ultrasound (US) acquisition and for the generation of complex anatomies.Results: Two experiments were set up to validate the proposed methodology. First, the accuracy of the manufacturing approach was assessed through the comparison between a post-production CT and the virtual references. The results proved that the silicone-based model was more accurate than the PVA-C-based one, with an error of 1.68±0.79, 1.36±0.94, 1.45±0.77 mm for the left (LA) and right atria (RA) and IAS, respectively. Secondly, an US acquisition of each model was performed and the obtained images quantitatively and qualitatively assessed. Both models showed a similar performance in terms of visual evaluation, with an easy detection of the LA, RA and the IAS. Furthermore, a moderate accuracy was obtained between the atrial surfaces extracted from the US and the ideal reference, and again a superior performance of the silicone-based model against the PVA-C phantom was found.Conclusions: The proposed strategy proved | |
dc.language.iso | eng | |
dc.rights | openAccess | |
dc.subject | Ciências Tecnológicas, Ciências médicas e da saúde | |
dc.subject | Technological sciences, Medical and Health sciences | |
dc.title | Development of a patient-specific atrial phantom model for planning and training of inter-atrial interventions | |
dc.type | Artigo em Revista Científica Internacional | |
dc.contributor.uporto | Faculdade de Engenharia | |
dc.identifier.doi | 10.1002/mp.12559 | |
dc.subject.fos | Ciências médicas e da saúde | |
dc.subject.fos | Medical and Health sciences | |
Appears in Collections: | FEUP - Artigo em Revista Científica Internacional |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
225381.1.pdf | Paper draft | 10.23 MB | Adobe PDF | View/Open |
225381.png | 1st Page | 568.15 kB | image/png | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.