Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/99496
Full metadata record
DC FieldValueLanguage
dc.creatorAntónio Rocha e Silva
dc.creatorClito Afonso
dc.date.accessioned2024-05-20T23:08:25Z-
dc.date.available2024-05-20T23:08:25Z-
dc.date.issued2004
dc.identifier.issn0378-7788
dc.identifier.othersigarra:65684
dc.identifier.urihttps://hdl.handle.net/10216/99496-
dc.description.abstractOne of the most feasible ways to measure duct airflows is by tracer gas techniques, especially for complex situations when the duct lengths are short as well as their access, which makes extremely difficult or impossible other methods to be implemented. One problem associated with the implementation of tracer gas technique when the ducts lengths are short is due to the impossibility of achieving complete mixing of the tracer with airflow and its sampling. In this work, the development of a new device for the injection of tracer gas in ducts is discussed as well as a new tracer-sampling device. The developed injection device has a compact tubular shape, with magnetic fixation to be easy to apply in duct walls. An array of sonic micro jets in counter current direction, with the possibility of angular movement according to its main axle ensures a complete mixing of the tracer in very short distances. The tracer-sampling device, with a very effective integration function, feeds the sampling system for analysis. Both devices were tested in a wind tunnel of approximately 21m total length. The tests distances between injection and integration device considered were: X/Dh = 22; X/Dh = 4; X/Dh = 2; and X/Dh = 1. For very short distances of X/Dh = 2 and X/Dh = 1, semi-empirical expressions were needed. A good reproducibility of airflow rate values was obtained. These preliminary tests showed that the practical implementation of tracer gas techniques in HVAC systems for measuring airflow rates with a very short mixing distance is possible with the devices developed. (c) 2004 Elsevier B.V. All rights reserved.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectOutras ciências da engenharia e tecnologias
dc.subjectOther engineering and technologies
dc.titleTracer Gas Dispersion in Ducts - Study of a New Compact Device using Arrays of Sonic Micro Jets
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/j.enbuild.2004.04.005
dc.subject.fosCiências da engenharia e tecnologias::Outras ciências da engenharia e tecnologias
dc.subject.fosEngineering and technology::Other engineering and technologies
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
65684.pdf
  Restricted Access
6.8 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.