dc.descriptionA humidade constitui uma das principais causas de deterioração dos edifícios, em particular, a variação da humidade relativa do ambiente interior. Nos museus, os objectos que constituem o seu acervo são facilmente afectados pelas variações de humidade relativa, pelo que é da maior importância avaliar a sua variação e controlo ao longo do tempo. Com este trabalho pretende-se analisar e avaliar as condições higrotérmicas de um museu sem sistemas de climatização permanente, bem como estudar experimentalmente, através de ensaios laboratoriais o controlo passivo das flutuações da humidade relativa no interior de um compartimento. O trabalho aqui desenvolvido procura evidenciar que a utilização de materiais higroscópicos nos revestimentos interiores dos museus favorece o controlo das condições higrotérmicas. Procura ainda contribuir para a aplicação deste princípio na reabilitação adaptativa de museus situados em edifícios antigos. PALAVRAS-CHAVE: Humidade Relativa, Museus, Inércia Higroscópica.
dc.description.abstractMoisture is one of the main causes of deterioration in buildings, especially the variations in relative humidity of the indoor air. In buildings that are used for special purposes, such as museums, and which do not have permanent air-conditioning systems, these variations in relative humidity may affect the works of art kept in their collections. The Laboratory of Building Physics (LFC) of the Faculty of Engineering, University of Oporto (FEUP), has been engaged in important research in the area of Hygroscopic Inertia. Its recent participation in the international research project Annex 41 - Whole Building Heat, Air and Moisture, organised by the International Energy Agency, has contributed to significant advances in the control of indoor hygrothermal conditions in a museum, with sole and exclusive recourse to the building. The aim of this work is to analyse and assess the hygrothermal conditions of a museum that is not equipped with permanent air-conditioning, and, by experimental research, study the passive effect of the building on the control of indoor hygrothermal conditions. It goal to prove that the use of hygroscopic materials in museum's interior finishing contributes to the control of hygrothermal conditions, a principle which, it is hoped, may be applied to the adaptive rehabilitation of museums located in old buildings. KEYWORDS: Relative Humidity, Museums, Hygroscopic Inertia.
dc.language.isopor
dc.rightsrestrictedAccess
dc.subjectEngenharia civil
dc.subjectCivil engineering
dc.titleImportância da Inércia Higroscópica em Museus
dc.typeDissertação
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.34626/yx3f-zm78
dc.subject.fosCiências da engenharia e tecnologias::Engenharia civil
dc.subject.fosEngineering and technology::Civil engineering