Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/94655
Full metadata record
DC FieldValueLanguage
dc.creatorM. A. S. Jerónimo
dc.creatorL. F. Melo
dc.creatorA. Sousa Braga
dc.creatorP. J. B. F. Ferreira
dc.creatorC. Martins
dc.date.accessioned2019-02-07T15:14:44Z-
dc.date.available2019-02-07T15:14:44Z-
dc.date.issued1997
dc.identifier.issn0894-1777
dc.identifier.othersigarra:55363
dc.identifier.urihttps://repositorio-aberto.up.pt/handle/10216/94655-
dc.description.abstractFouling is a problem whether we are aware of it or not. In an industrial plant, it is important not only to be able to measure the buildup of unwanted deposits, but also to do it in the simplest and most economically possible way. This paper addresses the question of monitoring fouling in an oil refinery plant, where the high number of heat exchanger units and the variability of the feedstock charge pose additional problems in terms of the practicability of following the energetic performance of such equipment. In this case, the flow rates and quality of the fluids flowing through the heat exchangers do not usually correspond to the design conditions, because they change with time. Therefore, to assess the fouling level of the exchangers, the day-to-day measured thermal efficiency should not be compared with the efficiency predicted in the design calculations. The latter should be recalculated by introducing whenever necessary new values of flow rates, physical properties, and so forth, and by evaluating new heat transfer coefficients. However, the procedures are too time consuming to be applied frequently. The present work describes a simplified method for following heat exchanger performances, based on the assessment of the number of transfer units and thermal efficiencies, where the effects of changing the feedstock charge, particularly the flow rates of the fluids, are taken into account. The only data that need to be collected are the four inlet/outlet temperatures of the heat exchanger unit and one of the flow rates. Several heat exchanger units in an oil refinery were successfully monitored by means of this method, and it was found that the variations in the physical properties did not significantly affect the results obtained for the particular plant under study. (C) Elsevier Science Inc., 1997.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.titleMonitoring the thermal efficiency of fouled heat exchangers: A simplified method
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/s0894-1777(96)00146-x
dc.identifier.authenticusP-001-BGA
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
55363.pdf
  Restricted Access
636.92 kBAdobe PDF    Request a copy from the Author(s)


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.