Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10216/88011| Autor(es): | Jorge L. Lino César L. Silva João Sampaio Fernandes Paulo J. Almeida Ramiro C. Martins Filipe S. Silva |
| Título: | Comparative analysis of the wear of titanium/titanium and titanium/zirconia interfaces in implant/abutment assemblies after thermocycling and mechanical loading |
| Data de publicação: | 2016 |
| Resumo: | Objectives: Due to its hardness, zirconia abutments may damage the titanium of the implant's connection during its clinical use. This study aimed to assess the wear of the seating platforms of externally hexed titanium implants when connected to zirconia abutments comparing to titanium abutments, after thermocycling and mechanical loading (TCML). Methods: Six BNT (R) S4 external connection implants (Phibo (R) Dental Solutions, Barcelona, Spain) were selected and divided into two groups (n=3): TiCE, screwed to titanium abutments and ZrCE, screwed to zirconia abutments. The samples underwent thermocycling (5000 cycles; 5-55 degrees C) and mechanical loading (1.2 x 106 cycles; 88.8 N; 4 Hz). Before and after TCML, the seating platforms of the implants were analyzed by 3D profilometry in two areas to measure their topography based on the superficial analysis parameters (Sa and Sz) parameters, and were studied by scanning electron microscopy (SEM). Data were statistically analyzed by Mann-Whitney test (p <0.05). Results: No statistically significant differences were observed in the Sa and Sz values between the implants at initial state and after TCML (p = 0.573> 0.05 and p = 0.059). The abutment's material (titanium/zirconia) did not statistically significantly influence the Sa and Sz values after TCML (p = 0.886> 0.05 and p = 0.200, respectively). However, the SEM analysis reveals a mild wear in some vertices of the hex when connected to zirconia abutments. Conclusions: After simulating five years of clinical use, the externally hexed implants, analyzed by 3D profilometry, showed similar wear patterns in the corresponding seating platforms when connected to zirconia or titanium abutments. The SEM images showed zirconia particles being transferred to the implant, which requires further study. |
| DOI: | 10.1016/j.rpemd.2016.07.002 |
| URI: | https://hdl.handle.net/10216/88011 |
| Tipo de Documento: | Artigo em Revista Científica Nacional |
| Condições de Acesso: | restrictedAccess |
| Aparece nas coleções: | FEUP - Artigo em Revista Científica Nacional FMDUP - Artigo em Revista Científica Nacional |
Ficheiros deste registo:
| Ficheiro | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| 166344.pdf Restricted Access | 3.01 MB | Adobe PDF | Ver/Abrir |
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.