Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/87052
Full metadata record
DC FieldValueLanguage
dc.creatorJorge L. Alves
dc.creatorCésar L. Silva
dc.creatorJoão Sampaio Fernandes
dc.creatorFilipe S. Silva
dc.creatorPaulo J. Almeida
dc.creatorRamiro C. Martins
dc.date.accessioned2022-09-07T05:19:17Z-
dc.date.available2022-09-07T05:19:17Z-
dc.date.issued2016
dc.identifier.issn1646-2890
dc.identifier.othersigarra:166290
dc.identifier.urihttps://hdl.handle.net/10216/87052-
dc.description.abstractObjectives: Although implant abutments made of yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) show great predictability, some issues related to its aging require further study. The objective of this in vitro study is to assess the stability of 3Y-TZP zirconia implant abutments with two different implant connections when subjected to aging simulation through thermocycling and mechanical loading (TCML). Methods: Ten 3Y-TZP zirconia abutments were selected and equally divided into two groups (n = 5): CEZr, abutments for externally hexed implants; and CIZr, abutments for implants with an internal conical connection. The samples were subjected to thermocycling (5000 cycles; 5-55 ◦C) and mechanical loading (1.2 × 106 cycles; 88.8 N; 4 Hz). Before and after the aging procedures, X-ray diffraction (XRD) analysis was conducted to observe tetragonalmonoclinic (t-m) phase transformation, and topographic surface analysis was performed by 3D profilometry, and data were analyzed using Mann-Witney test (p < 0.05). Results: XRD measurements revealed no monoclinic phase in any of the abutments after aging. The comparative analysis regarding roughness (using the Sa parameter) at the abutments' seating platforms (using 3D profilometry) revealed a slight increase in roughness in both connections after TCML. Statistically significant differences (test U = 57.0, p = 0.161 > 0.05), before and after TCML, and between implants connections (test U = 57.0, p = 0.053 > 0.05) were not detected. Conclusions: After a 5-year simulation of its clinical use, the analyzed 3Y-TZP zirconia abutments did not show signs of aging. The connection's geometry does not interfere in aging.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectCiências da Saúde, Ciências médicas e da saúde
dc.subjectHealth sciences, Medical and Health sciences
dc.titleAnalysis of the Stability of 3Y-TZP Zirconia Abutments After Thermocycling and Mechanical Loading
dc.typeArtigo em Revista Científica Nacional
dc.contributor.uportoFaculdade de Engenharia
dc.contributor.uportoFaculdade de Medicina Dentária
dc.identifier.doi10.1016/j.rpemd.2016.07.003
dc.identifier.authenticusP-00M-A8M
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Appears in Collections:FEUP - Artigo em Revista Científica Nacional
FMDUP - Artigo em Revista Científica Nacional

Files in This Item:
File Description SizeFormat 
166290.pdf
  Restricted Access
3.01 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.