Please use this identifier to cite or link to this item:
https://hdl.handle.net/10216/87045Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.creator | Jonatan R. Ruiz | |
| dc.creator | Gustavo Silva | |
| dc.creator | Norton Oliveira | |
| dc.creator | José C. Ribeiro | |
| dc.creator | José F. Oliveira | |
| dc.creator | Jorge Mota | |
| dc.date.accessioned | 2019-02-05T07:49:40Z | - |
| dc.date.available | 2019-02-05T07:49:40Z | - |
| dc.date.issued | 2009 | |
| dc.identifier.issn | 0264-0414 | |
| dc.identifier.other | sigarra:45309 | |
| dc.identifier.uri | https://repositorio-aberto.up.pt/handle/10216/87045 | - |
| dc.description.abstract | We assessed the agreement between maximal oxygen consumption ([Vdot]O2max) measured directly when performing the 20-m shuttle run test and estimated [Vdot]O2max from five different equations (i.e. Barnett, equations a and b; Leger; Matsuzaka; and Ruiz) in youths. The 20-m shuttle run test was performed by 26 girls (mean age 14.6 years, s=1.5; body mass 57.2kg, s=8.9; height 1.60m, s=0.06) and 22 boys (age 15.0 years, s=1.6; body mass 63.5kg, s=11.5; height 1.70m, s=0.01). The participants wore a portable gas analyser (K4b2, Cosmed) to measure [Vdot]O2 during the test. All the equations significantly underestimated directly measured [Vdot]O2max, except Barnett's (b) equation. The mean difference ranged from 1.3ml center dot kg-1 center dot min-1 (Barnett (b)) to 5.5ml center dot kg-1 center dot min-1 (Leger). The standard error of the estimate ranged from 5.3ml center dot kg-1 center dot min-1 (Ruiz) to 6.5ml center dot kg-1 center dot min-1 (Leger), and the percentage error ranged from 21.2% (Ruiz) to 38.3% (Leger). The accuracy of the equations available to estimate [Vdot]O2max from the 20-m shuttle run test is questionable at the individual level. Furthermore, special attention should be paid when comparisons are made between studies (e.g. population-based studies) using different equations. The results of the present study suggest that Barnett's (b) equation provides the closest agreement with directly measured [Vdot]O2max (cardiorespiratory fitness) in youth. | |
| dc.language.iso | eng | |
| dc.rights | restrictedAccess | |
| dc.subject | Ciências da saúde | |
| dc.subject | Health sciences | |
| dc.title | Criterion-related validity of the 20-m shuttle run test in youths aged 13-19 years | |
| dc.type | Artigo em Revista Científica Internacional | |
| dc.contributor.uporto | Faculdade de Desporto | |
| dc.identifier.doi | 10.1080/02640410902902835 | |
| dc.identifier.authenticus | P-003-R3H | |
| dc.subject.fos | Ciências médicas e da saúde::Ciências da saúde | |
| dc.subject.fos | Medical and Health sciences::Health sciences | |
| Appears in Collections: | FADEUP - Artigo em Revista Científica Internacional | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 45309.pdf Restricted Access | 301.07 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.