Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/85435
Full metadata record
DC FieldValueLanguage
dc.creatorPedro Pedrosa Rebouças Filho
dc.creatorPaulo César Cortez
dc.creatorAntônio C. da Silva Barros
dc.creatorVictor Hugo C. Albuquerque
dc.creatorJoão Manuel R. S. Tavares
dc.date.accessioned2022-09-08T04:09:34Z-
dc.date.available2022-09-08T04:09:34Z-
dc.date.issued2017-01
dc.identifier.issn1361-8415
dc.identifier.othersigarra:143847
dc.identifier.urihttps://hdl.handle.net/10216/85435-
dc.description.abstractThe World Health Organization estimates that 300 million people have asthma, 210 million people have Chronic Obstructive Pulmonary Disease (COPD), and, according to WHO, COPD will become the third major cause of death worldwide in 2030. Computational Vision systems are commonly used in pulmonology to address the task of image segmentation, which is essential for accurate medical diagnoses. Segmentation defines the regions of the lungs in CT images of the thorax that must be further analyzed by the system or by a specialist physician. This work proposes a novel and powerful technique named 3D Adaptive Crisp Active Contour Method (3D ACACM) for the segmentation of CT lung images. The method starts with a sphere within the lung to be segmented that is deformed by forces acting on it towards the lung borders. This process is performed iteratively in order to minimize an energy function associated with the 3D deformable model used. In the experimental assessment, the 3D ACACM is compared against three approaches commonly used in this field: the automatic 3D Region Growing, the level-set algorithm based on coherent propagation and the semi-automatic segmentation by an expert using the 3D OsiriX toolbox. When applied to 40 CT scans of the chest the 3D ACACM had an average F-measure of 99.22%, revealing its superiority and competency to segment lungs in CT images.
dc.language.isoeng
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/
dc.subjectCiências Tecnológicas, Ciências da engenharia e tecnologias
dc.subjectTechnological sciences, Engineering and technology
dc.titleNovel and powerful 3D adaptive crisp active contour method applied in the segmentation of CT lung images
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/j.media.2016.09.002
dc.subject.fosCiências da engenharia e tecnologias
dc.subject.fosEngineering and technology
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
143847.png1st Page413.65 kBimage/pngThumbnail
View/Open
143847.1.pdfPaper6.98 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons