Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/82986
Full metadata record
DC FieldValueLanguage
dc.creatorTaras Kotyk
dc.creatorNilanjan Dey
dc.creatorAmira S. Ashour
dc.creatorDana Balas-Timar
dc.creatorSayan Chakraborty
dc.creatorAhmed S. Ashour
dc.creatorJoão Manuel R. S. Tavares
dc.date.accessioned2022-09-07T15:16:43Z-
dc.date.available2022-09-07T15:16:43Z-
dc.date.issued2016
dc.identifier.issn0169-2607
dc.identifier.othersigarra:120582
dc.identifier.urihttps://hdl.handle.net/10216/82986-
dc.description.abstractGlomerulus diameter and Bowman's space width in renal microscopic images indicate various diseases. Therefore, the detection of the renal corpuscle and related objects is a key step in histopathological evaluation of renal microscopic images. However, the task of automatic glomeruli detection is challenging due to their wide intensity variation, besides the inconsistency in terms of shape and size of the glomeruli in the renal corpuscle. Here, a novel solution is proposed which includes the Particles Analyzer technique based on median filter for morphological image processing to detect the renal corpuscle objects. Afterwards, the glomerulus diameter and Bowman's space width are measured. The solution was tested with a dataset of 21 rats' renal corpuscle images acquired using light microscope. The experimental results proved that the proposed solution can detect the renal corpuscle and its objects efficiently. As well as, the proposed solution has the ability to manage any input images assuring its robustness to the deformations of the glomeruli even with the glomerular hypertrophy cases. Also, the results reported significant difference between the control and affected (due to ingested additional daily dose (14.6mg) of fructose) groups in terms of glomerulus diameter (97.40 ± 19.02m and 177.03 ± 54.48m, respectively).
dc.language.isoeng
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/
dc.subjectCiências Tecnológicas, Ciências médicas e da saúde
dc.subjectTechnological sciences, Medical and Health sciences
dc.titleMeasurement of glomerulus diameter and Bowman's space width of renal albino rats
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/j.cmpb.2015.10.023
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
120582.pdfPaper1.82 MBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons