Please use this identifier to cite or link to this item: http://hdl.handle.net/10216/67678
Author(s): C. Carneiro
F. Oliveira
J. Nogueira
A. Mendes
Title: Permeability of Paint Films towards Chloride Ion
Issue Date: 2006
Abstract: Art apparatus for determining tire permeability of paint films towards chloride ion is described. This set-lip implements tire time-lag method and consists of a permeation cell made tip of two chambers divided by a supported paint film. The upper chamber contains air aqueous sodium chloride solution and tire lower one, water. The permeability is obtained front the conductivity history read at tire lower chamber. Osmotic pressure issue is addressed and tire reproducibility of the results reported.The time-lag method is not described in any standard. The requirement concerning "surface protection systems for concrete" for chloride ion permeability is not quantified in prEN 1504-2. The standard establishes that this requirement is "subject to national standards and national regulations" but when tire capillary adsorption of water is lower than 0.01 kg(m(2)h(05)) the diffusion of chloride ion is not to be expected. Some experimental results prove this is not correct and, in Portugal, the National Laboratory of Civil Engineering (LNEC) has proposed a threshold permeability value of 10(-14) m(2)/sec for coatings claiming to be corrosion protective.
Subject: Tecnologia química, Outras ciências da engenharia e tecnologias
URI: http://hdl.handle.net/10216/67678
Document Type: Artigo em Revista Científica Internacional
Rights: openAccess
License: https://creativecommons.org/licenses/by-nc/4.0/
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
65298.pdf187.91 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons