Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/24386
Full metadata record
DC FieldValueLanguage
dc.creatorDaniel C. Moura
dc.creatorJorge G. Barbosa
dc.creatorAna M. Reis
dc.creatorJoão Manuel R. S. Tavares
dc.date.accessioned2019-02-01T02:46:28Z-
dc.date.available2019-02-01T02:46:28Z-
dc.date.issued2010
dc.identifier.issn1526-1492
dc.identifier.othersigarra:62683
dc.identifier.urihttps://repositorio-aberto.up.pt/handle/10216/24386-
dc.description.abstractThis paper presents a new method for the calibration of biplanar radiography that makes possible performing 3D reconstructions of the spine using conventional radiological systems. A novel approach is proposed in which a measuring device is used for determining focal distance and have a rough estimation of translation parameters. Using these data, 3D reconstructions of the spine with correct scale were successfully obtained without the need of calibration objects, something that was not previously achieved. For superior results, two optional steps may be executed that involve an optimisation of the geometrical parameters, followed by a scale adjustment with a very simple calibration object. Computer simulations with in vivo CT data show RMS 3D reconstruction errors of 1.9 mm when under the maximum expected variation of the geometrical parameters of the radiological system. Simulations also show that the 3D spinal length may be accurately calculated, but with superior results when using optimisation and adjusting scale (RMS error of 2.09 mm). In vitro experiments with a dried spine composed by 17 vertebrae show mean 3D reconstructions errors of 1.7 mm. We conclude that the proposed method is suitable for use in clinical environment, and that it compares favourably with previous calibration techniques.
dc.language.isoeng
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/
dc.subjectCiências Tecnológicas, Outras ciências da engenharia e tecnologias
dc.subjectTechnological sciences, Other engineering and technologies
dc.titleA Flexible Approach for the Calibration of Biplanar Radiography of the Spine on Conventional Radiological Systems
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.authenticusP-003-6X4
dc.subject.fosCiências da engenharia e tecnologias::Outras ciências da engenharia e tecnologias
dc.subject.fosEngineering and technology::Other engineering and technologies
Appears in Collections:FEUP - Artigo em Revista Científica Internacional