Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/23364
Author(s): António Pedro Oliveira de Carvalho
Pedro Miguel Aguiar da Silva
Title: Sound, noise and speech at the 9000-seat Holy Trinity Church in Fatima, Portugal
Issue Date: 2010
Abstract: This paper presents the interior acoustical characterization of the 9,000-seat church of the Holy Trinity in the Sanctuary of Fátima, Portugal, inaugurated in 2007. In situ measurements were held regarding interior sound pressure levels (with and without the HVAC equipment working), NC curves, RASTI (with and without the installed sound system) and reverberation time. The results are presented and commented according to the design values. A comparison is made with other churches in the world also with a very large volume (for instance the Basilica Mariacka in Gdask). The measured data are also used to calculate a global index of this church acoustic quality using Engel and Kosalas Index Method.
Subject: Acústica, Engenharia civil
Acoustics, Civil engineering
Scientific areas: Ciências da engenharia e tecnologias::Engenharia civil
Engineering and technology::Civil engineering
DOI: 10.2478/v10168-010-0013-5
URI: https://hdl.handle.net/10216/23364
Document Type: Artigo em Revista Científica Internacional
Rights: openAccess
License: https://creativecommons.org/licenses/by-nc/4.0/
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
62560.pdfArchives of Acoustics 35(2)722.11 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons