Please use this identifier to cite or link to this item:
https://hdl.handle.net/10216/167139Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.creator | Maria Francisca Cunha | |
| dc.creator | Sara Ramos | |
| dc.creator | Adrián M. T. Silva | |
| dc.creator | Pedro Norton | |
| dc.creator | Arminda Alves | |
| dc.creator | Mónica Santos | |
| dc.date.accessioned | 2025-06-26T23:10:50Z | - |
| dc.date.available | 2025-06-26T23:10:50Z | - |
| dc.date.issued | 2021 | |
| dc.identifier.issn | 1424-8247 | |
| dc.identifier.other | sigarra:502446 | |
| dc.identifier.uri | https://hdl.handle.net/10216/167139 | - |
| dc.description.abstract | Cytostatics are drugs used in cancer treatment, which pose serious risks to healthcare workers. Dermal absorption via surface contamination is the key exposure route; thus, rapid, reliable, and validated analytical methods for multicomponent detection are crucial to identify the exposure risk. A surface-wipe-sampling technique compatible with hospitals' safety requirements (gauze, 1 mL isopropanol) and a fast and simple extraction method (1 mL acetonitrile, 20 min ultrasonic bath, evaporation, reconstitution in 200 mu L acetonitrile), coupled with liquid chromatography-tandem mass spectrometry analysis, were developed. It allowed identification and quantification of 13 cytostatics on surfaces: cyclophosphamide, doxorubicin, etoposide, ifosfamide, paclitaxel, bicalutamide, capecitabine, cyproterone, flutamide, imatinib, megestrol, mycophenolate mofetil, prednisone. Good linearity, sensitivity, and precision were achieved (R-2 > 0.997, IDLs < 4.0 pg/cm(2), average CV 16%, respectively). Accuracy for four model surfaces (melamine-coated wood, phenolic compact, steel 304, steel 316) was acceptable (80 +/- 12%), except for capecitabine and doxorubicin. Global uncertainty is below 35% for concentrations above 100 pg/cm(2) (except for capecitabine and doxorubicin)-a guidance value for relevant contamination. Method application in a Portuguese university hospital (28 samples) identified the presence of seven cytostatics, at concentrations below 100 pg/cm(2), except for three samples. The widespread presence of cyclophosphamide evinces the necessity to review implemented procedures. | |
| dc.language.iso | eng | |
| dc.rights | openAccess | |
| dc.title | An Improved LC-MS/MS Method for the Analysis of Thirteen Cytostatics on Workplace Surfaces | |
| dc.type | Artigo em Revista Científica Internacional | |
| dc.contributor.uporto | Faculdade de Engenharia | |
| dc.identifier.doi | 10.3390/ph14080754 | |
| dc.identifier.authenticus | P-00V-C9H | |
| Appears in Collections: | FEUP - Artigo em Revista Científica Internacional | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 502446.pdf | 3.27 MB | Adobe PDF | ![]() View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
