Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/154149
Author(s): Moller, P
Azqueta, A
Collia, M
Bakuradze, T
Richling, E
Bankoglu, EE
Stopper, H
Bastos, VC
Langie, SAS
Jensen, A
Ristori, S
Scavone, F
Giovannelli, L
Wojewódzka, M
Kruszewski, M
Valdiglesias, V
Laffon, B
Costa, C
Costa, S
Teixeira, JP
Marino, M
Del Bo, C
Riso, P
Zheng, CY
Shaposhnikov, S
Collins, A
Title: Inter-laboratory variation in measurement of DNA damage by the alkaline comet assay in the hCOMET ring trial
Publisher: Oxford University Press
Issue Date: 2023
Abstract: The comet assay is a simple and versatile method for measurement of DNA damage in eukaryotic cells. More specifically, the assay detects DNA migration from agarose gel-embedded nucleoids, which depends on assay conditions and the level of DNA damage. Certain steps in the comet assay procedure have substantial impact on the magnitude of DNA migration (e.g. electric potential and time of electrophoresis). Inter-laboratory variation in DNA migration levels occurs because there is no agreement on optimal assay conditions or suitable assay controls. The purpose of the hCOMET ring trial was to test potassium bromate (KBrO3) as a positive control for the formamidopyrimidine DNA glycosylase (Fpg)-modified comet assay. To this end, participating laboratories used semi-standardized protocols for cell culture (i.e. cell culture, KBrO3 exposure, and cryopreservation of cells) and comet assay procedures, whereas the data acquisition was not standardized (i.e. staining of comets and image analysis). Segregation of the total variation into partial standard deviation (SD) in % Tail DNA units indicates the importance of cell culture procedures (SD = 10.9), comet assay procedures (SD = 12.3), staining (SD = 7.9) and image analysis (SD = 0.5) on the overall inter-laboratory variation of DNA migration (SD = 18.2). Future studies should assess sources of variation in each of these steps. On the positive side, the hCOMET ring trial demonstrates that KBrO3 is a robust positive control for the Fpg-modified comet assay. In conclusion, the hCOMET ring trial has demonstrated a high reproducibility of detecting genotoxic effects by the comet assay, but inter-laboratory variation of DNA migration levels is a concern.
Subject: Comet assay
DNA damage
inter-laboratory variation
ring trial
validation
DOI: 10.1093/mutage/gead014
URI: https://hdl.handle.net/10216/154149
Source: Mutagenesis. 2023 Oct 14;38(5):283-294. doi: 10.1093/mutage/gead014.
Document Type: Artigo em Revista Científica Internacional
Rights: openAccess
Appears in Collections:ISPUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
moller-m2023.pdf2.26 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.