Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/149681
Author(s): Garrido, MM
Ribeiro, R
Pinheiro, LC
Holdenrieder, S
Guimarães, JT
Title: The prostate health index and the percentage of [-2]proPSA maintain their diagnostic performance when calculated with total and free PSA from different manufacturers
Publisher: De Gruyter
Issue Date: 2021
Abstract: Objectives To evaluate the diagnostic performance of the prostate health index (PHI) and of the percentage of [-2]proPSA (%[-2]proPSA) calculated with total and free PSA from non-Beckman Coulter manufacturers (Roche and Abbott), and compare it with the fully Beckman Coulter [-2]proPSA derivatives. Methods In this study, 237 men (PSA: 2–10 μg/L) scheduled for prostate biopsy were enrolled. %[-2]proPSA and PHI were calculated with total and free PSA from three manufacturers. Beckman Coulter PSA and [-2]proPSA were performed on the Access 2 analyzer (Hybritech calibration). Roche PSA was performed on the cobas e411 and the Abbott PSA on the Architect i2000sr. Statistical analysis was performed, considering prostate cancer (PCa) as the outcome. Results Univariate analysis showed that all indices were predictors of cancer, irrespective of the manufacturer (p<0.001). The AUC was similar for all manufacturers, both for %[-2]proPSA (Beckman Coulter: 0.756; Roche: 0.770; Abbott: 0.756) and PHI (Beckman Coulter: 0.776; Roche: 0.785; Abbott: 0.778). When considering the cutoffs that allowed 90% sensitivity, [-2]proPSA derivatives calculated with Roche and Abbott PSA had similar specificities and predictive values when compared to Beckman Coulter. The percentage of missed cancers (8–9%) was the same between manufacturers. The percentage of spared biopsies was significantly higher with Roche’s PHI (21.0%) and Abbott’s PHI (20.6%) than with Beckman Coulter’s PHI (17.2%). Conclusions In the PSA range between 2 and 10 μg/L, [-2]proPSA derivatives maintain their diagnostic performance in PCa detection when calculated with PSA from Roche and Abbott. This can lead to a broader implementation of these indices in clinical laboratories worldwide.
Subject: [2]proPSA
prostate cancer
prostate health index
several manufacturers
DOI: 10.1515/cclm-2021-0554
URI: https://hdl.handle.net/10216/149681
Source: Clin Chem Lab Med. 2021 Jul 27;59(11):1869-1877
Document Type: Artigo em Revista Científica Internacional
Rights: restrictedAccess
License: https://creativecommons.org/licenses/by/4.0/
Appears in Collections:ISPUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
garrido-cclm-2021.pdf
  Restricted Access
850.04 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons