Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10216/149472Registo completo
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.creator | Monteiro, A | |
| dc.creator | Almeida, B | |
| dc.creator | Paciência, I | |
| dc.creator | Cavaleiro Rufo, J | |
| dc.creator | Ribeiro, E | |
| dc.creator | Carolino, E | |
| dc.creator | Viegas, C | |
| dc.creator | Uva, AS | |
| dc.creator | Verde, SC | |
| dc.date.accessioned | 2023-05-23T14:23:14Z | - |
| dc.date.available | 2023-05-23T14:23:14Z | - |
| dc.date.issued | 2021 | |
| dc.identifier.issn | 2073-4433 | |
| dc.identifier.uri | https://hdl.handle.net/10216/149472 | - |
| dc.description.abstract | This study aims to assess the airborne bioburden of rural and urban Portuguese Primary Health Care Centers (PHCC) using active and passive sampling methods and identify the potential differences in airborne microbiota between both environments. The highest total aerobic mesophilic bacterial load in indoor air were found in the Vaccination Room (448 CFU.m−3) in the Rural PHCC and in the Waiting Room (420 CFU.m−3) for Urban PHCC. The total coliforms contamination level in indoor air was detected only in the Cleaning Supplies Room (4 CFU.m−3) in the Urban PHCC. The most frequent bacteria genera identified was Micrococcus (21% Rural PHCC; 31% Urban PHCC). The surface samples showed a highest total aerobic mesophilic bacterial contamination in the Treatment Room (86 × 103 CFU.m−2) from the Rural PHCC and in the Front Office (200 × 103 CFU.m−2) from the Urban PHCC. The electrostatic dust cloth (EDC) samples showed a highest bacterial load in the Urban PHCC. Total aerobic mesophilic bacterial load in settled dust and in the Heating, Ventilating and Air Conditioning (HVAC) filter samples in the Urban PHCC (8 CFU.g−1 and 6 × 103 CFU.m−2) presented higher values compared with the Rural PHCC (1 CFU.g−1 and 2.5 × 103 CFU.m−2). Urban PHCC presented higher bacterial airborne contamination compared with the Rural PHCC for the majority of sampling sites, and when compared with the indoor air quality (IAQ) Portuguese legislation it was the Rural PHCC in two sampling places who did not comply with the established criteria. | |
| dc.description.sponsorship | H&TRC authors gratefully acknowledge the FCT/MCTES national support through the UIDB/05608/2020 and UIDP/05608/2020. The FCT support is also acknowledged by C2TN/IST (UIDB/04349/2020þUIDP/04349/2020). | |
| dc.language.iso | eng | |
| dc.publisher | MDPI | |
| dc.relation | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB/05608/2020/PT | |
| dc.relation | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP/05608/2020/PT | |
| dc.relation | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB/04349/2020/PT | |
| dc.relation | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP/04349/2020/PT | |
| dc.relation.ispartof | Atmosphere 2021, 12(4), 450 | |
| dc.rights | openAccess | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | Primary Health Care Centers | |
| dc.subject | airborne bacteria | |
| dc.subject | antibiotic resistance profile | |
| dc.subject | urban | |
| dc.subject | rural | |
| dc.title | Bacterial contamination in health care centers: Differences between urban and rural settings | |
| dc.type | Artigo em Revista Científica Internacional | |
| dc.contributor.uporto | Instituto de Saúde Pública da Universidade do Porto | |
| dc.identifier.doi | 10.3390/atmos12040450 | |
| dc.relation.publisherversion | https://www.mdpi.com/2073-4433/12/4/450/htm | |
| Aparece nas coleções: | ISPUP - Artigo em Revista Científica Internacional | |
Ficheiros deste registo:
| Ficheiro | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| monteiro-a-2021.pdf | 727.75 kB | Adobe PDF | ![]() Ver/Abrir |
Este registo está protegido por Licença Creative Commons
