Please use this identifier to cite or link to this item:
https://hdl.handle.net/10216/141431Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.creator | Matos, AM | |
| dc.creator | Figueiredo, SC | |
| dc.creator | Sandra Nunes | |
| dc.creator | Schlangen, E | |
| dc.creator | Barroso Aguiar, JL | |
| dc.date.accessioned | 2022-09-15T07:59:48Z | - |
| dc.date.available | 2022-09-15T07:59:48Z | - |
| dc.date.issued | 2021 | |
| dc.identifier.issn | 0950-0618 | |
| dc.identifier.other | sigarra:530165 | |
| dc.identifier.uri | https://hdl.handle.net/10216/141431 | - |
| dc.description.abstract | The high cost of UHPFRC is a limitation on the practical application in real construction projects. However, a very competitive UHPFRC approach is the hybrid structural elements, where thin layers of UHPFRC are employed to rehabilitate/strengthen damage cover concrete. New layers subjected to harsh conditions (loads and/or environmental) can eventually crack under service conditions, changing the local transport properties and thus, a faster ingress of detrimental substances occur, such as chlorides ions. Most of the studies on chloride penetration in UHPFRC have focused on determining the transport properties of sound, non-cracked specimens. Thus, an experimental campaign was carried out to assess chloride ingress in loaded and/or cracked UHPFRC and the effect of such ions on mechanical performance. Typical service cracks patterns were imposed on UHPFRC specimens and then exposed to wetting-drying cycles in a chloride solution. After 1-year chloride exposure, UHPFRC specimens were in good condition with no significant losses in flexural strength; however, stiffness might be affected. The chloride contents up to 20 mm depth were superior to the European standards critical chloride content. A minimum cover depth of 20 mm of new UHPFRC is recommended to protect a concrete substrate in hybrid structures for exposure classes XS3. | |
| dc.language.iso | eng | |
| dc.rights | restrictedAccess | |
| dc.title | Durability of an UHPFRC under mechanical and chloride loads | |
| dc.type | Artigo em Revista Científica Internacional | |
| dc.contributor.uporto | Faculdade de Engenharia | |
| dc.identifier.doi | 10.1016/j.conbuildmat.2021.125223 | |
| dc.identifier.authenticus | P-00V-M5P | |
| Appears in Collections: | FEUP - Artigo em Revista Científica Internacional | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 530165.pdf Restricted Access | 12.46 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.