| dc.description.abstract | This work presents a new concept of facades coated with machined ETIC boards displaying tilted strips. Strips with upwards tilt have a high total solar reflectance (TSR) paint, to maximize the solar radiation reflection during the summer period. Strips tilted downwards have a low TSR paint, to maximize the solar absorption during wintertime. Parameters that characterize this new tilted strips ETIC system (TiS-ETICS) were optimized for four different locations: Porto, Sao Paulo, Los Angeles, and Sydney. The indoor temperature, in the free-floating mode, and the energy demand needed over the year, in conditioned mode, were both assessed through building simulation. The use of TiS-ETICS, compared to pristine facades, always led to a positive impact on performance. In free-floating mode, with the new system, indoor temperatures dropped in summer and increased in winter. In conditioned mode, annual energy savings between 10.8% (in Porto) and 32.3% (Sao Paulo) were obtained. | |
| dc.language.iso | eng | |
| dc.rights | restrictedAccess | |
| dc.subject | Química, Engenharia química | |
| dc.subject | Chemistry, Chemical engineering | |
| dc.title | A new tilted strips external thermal insulation composite system (TiS-ETICS): Description and performance assessment through thermal and energy simulation for a residential building | |
| dc.type | Artigo em Revista Científica Internacional | |
| dc.contributor.uporto | Faculdade de Engenharia | |
| dc.identifier.doi | 10.1016/j.jobe.2020.101953 | |
| dc.identifier.authenticus | P-00T-CE7 | |
| dc.subject.fos | Ciências da engenharia e tecnologias::Engenharia química | |
| dc.subject.fos | Engineering and technology::Chemical engineering | |
| Appears in Collections: | FEUP - Artigo em Revista Científica Internacional | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 553862.pdf Restricted Access | 1.47 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.