Please use this identifier to cite or link to this item:
https://hdl.handle.net/10216/136320| Author(s): | Paiva, JS Jorge, PAS Ribeiro, RSR Sampaio, P Rosa, CC Cunha, JPS |
| Title: | Optical fiber-based sensing method for nanoparticle detection through supervised back-scattering analysis: A potential contributor for biomedicine |
| Publisher: | Dove Medical Press |
| Issue Date: | 2019 |
| Abstract: | Background: In view of the growing importance of nanotechnologies, the detection/identification of nanoparticles type has been considered of utmost importance. Although the characterization of synthetic/organic nanoparticles is currently considered a priority (eg, drug delivery devices, nanotextiles, theranostic nanoparticles), there are many examples of “naturally” generated nanostructures - for example, extracellular vesicles (EVs), lipoproteins, and virus - that provide useful information about human physiology or clinical conditions. For example, the detection of tumor-related exosomes, a specific type of EVs, in circulating fluids has been contributing to the diagnosis of cancer in an early stage. However, scientists have struggled to find a simple, fast, and low-cost method to accurately detect/identify these nanoparticles, since the majority of them have diameters between 100 and 150 nm, thus being far below the diffraction limit. Methods: This study investigated if, by projecting the information provided from short-term portions of the back-scattered laser light signal collected by a polymeric lensed optical fiber tip dipped into a solution of synthetic nanoparticles into a lower features dimensional space, a discriminant function is able to correctly detect the presence of 100 nm synthetic nanoparticles in distilled water, in different concentration values. Results and discussion: This technique ensured an optimal performance (100% accuracy) in detecting nanoparticles for a concentration above or equal to 3.89 µg/mL (8.74E+10 particles/mL), and a performance of 90% for concentrations below this value and higher than 1.22E-03 µg/mL (2.74E+07 particles/mL), values that are compatible with human plasmatic levels of tumorderived and other types of EVs, as well as lipoproteins currently used as potential biomarkers of cardiovascular diseases. Conclusion: The proposed technique is able to detect synthetic nanoparticles whose dimensions are similar to EVs and other “clinically” relevant nanostructures, and in concentrations equivalent to the majority of cell-derived, platelet-derived EVs and lipoproteins physiological levels. This study can, therefore, provide valuable insights towards the future development of a device for EVs and other biological nanoparticles detection with innovative characteristics. |
| Subject: | Brownian motion Diffusive analysis Extracellular vesicles (evs) detection Light scattering effects Lipoproteins detection Nanoparticles Nanoparticles detection Optical fiber sensors Virus detection |
| DOI: | 10.2147/IJN.S174358 |
| URI: | https://hdl.handle.net/10216/136320 |
| Source: | International Journal of Nanomedicine, vol.14, p. 2349-2369 |
| Document Type: | Artigo em Revista Científica Internacional |
| Rights: | openAccess |
| License: | https://creativecommons.org/licenses/by-nc/3.0/ |
| Appears in Collections: | I3S - Artigo em Revista Científica Internacional |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 10.2147-IJN.S174358.pdf | 4.33 MB | Adobe PDF | ![]() View/Open |
This item is licensed under a Creative Commons License
