Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/127773
Full metadata record
DC FieldValueLanguage
dc.creatorDanilo Samuel Jodas
dc.creatorMaria Francisca Monteiro da Costa
dc.creatorTiago A. A. Parreira
dc.creatorAledir Silveira Pereira
dc.creatorJoão Manuel R. S. Tavares
dc.date.accessioned2023-05-08T23:35:13Z-
dc.date.available2023-05-08T23:35:13Z-
dc.date.issued2020-08
dc.identifier.issn0010-4825
dc.identifier.othersigarra:406266
dc.identifier.urihttps://hdl.handle.net/10216/127773-
dc.description.abstractSegmentation methods have assumed an important role in image-based diagnosis of several cardiovascular diseases. Particularly, the segmentation of the boundary of the carotid artery is demanded in the detection and characterization of atherosclerosis and assessment of the disease progression. In this article, a fully automatic approach for the segmentation of the carotid artery boundary in Proton Density Weighted Magnetic Resonance Images is presented. The approach relies on the expansion of the lumen contour based on a distance map built using the gray-weighted distance relative to the center of the identified lumen region in the image under analysis. Then, a Snake model with a modified weighted external energy based on the combination of a balloon force along with a Gradient Vector Flow-based external energy is applied to the expanded contour towards the correct boundary of the carotid artery. The average values of the Dice coefficient, Polyline distance, mean contour distance and centroid distance found in the segmentation of 139 carotid arteries were 0.83 +/- 0.11, 2.70 +/- 1.69 pixels, 2.79 +/- 1.89 pixels and 3.44 +/- 2.82 pixels, respectively. The segmentation results of the proposed approach were also compared against the ones obtained by related approaches found in the literature, which confirmed the outstanding performance of the new approach. Additionally, the proposed weighted external energy for the Snake model was shown to be also robust to carotid arteries with large thickness and weak boundary image edges.
dc.language.isoeng
dc.rightsopenAccess
dc.subjectCiências Tecnológicas, Ciências médicas e da saúde
dc.subjectTechnological sciences, Medical and Health sciences
dc.titleUsing a distance map and an active contour model to segment the carotid artery boundary from the lumen contour in proton density weighted magnetic resonance images
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/j.compbiomed.2020.103901
dc.identifier.authenticusP-00S-M6R
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
406266.jpg1st Page509.19 kBJPEGThumbnail
View/Open
406266.1.pdfPaper draft2.36 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.