Utilize este identificador para referenciar este registo: https://hdl.handle.net/10216/117998
Registo completo
Campo DCValorIdioma
dc.creatorPedro Morais
dc.creatorSandro Queirós
dc.creatorPieter De Meester
dc.creatorWerner Budts
dc.creatorJoão L. Vilaça
dc.creatorJoão Manuel R. S. Tavares
dc.creatorJan D'hooge
dc.date.accessioned2023-05-08T23:28:55Z-
dc.date.available2023-05-08T23:28:55Z-
dc.date.issued2018-12
dc.identifier.issn0885-3010
dc.identifier.othersigarra:304943
dc.identifier.urihttps://hdl.handle.net/10216/117998-
dc.description.abstractLeft atrial appendage (LAA) has been generally described as "our most lethal attachment," being considered the major source of thromboembolism in patients with nonvalvular atrial fibrillation. Currently, LAA occlusion can be offered as a treatment for these patients, obstructing the LAA through a percutaneously delivered device. Nevertheless, correct device sizing is not straightforward, requiring manual analysis of peri-procedural images. This approach is suboptimal, time demanding, and highly variable between experts, which can result in lengthy procedures and excess manipulations. In this paper, a semiautomatic LAA segmentation technique for 3-D transesophageal echocardiography (TEE) images is presented. Specifically, the proposed technique relies on a novel segmentation pipeline where a curvilinear blind-ended model is optimized through a double stage strategy: 1) fast contour evolution using global terms and 2) contour refinement based on regional energies. To reduce its computational cost, and thus make it more attractive to real interventions, the B-spline explicit active surface framework was used. This novel method was evaluated in a clinical database of 20 patients. Manual analysis performed by two observers was used as ground truth. The 3-D segmentation results corroborated the accuracy, robustness to the variation of the parameters, and computationally attractiveness of the proposed method, taking approximately 14 s to segment the LAA with an average accuracy of similar to 0.9 mm. Moreover, a performance comparable to the interobserver variability was found. Finally, the advantages of the segmented model were evaluated, while semiautomatically extracting the clinical measurements for device selection, showing a similar accuracy but with a higher reproducibility when compared to the current practice. Overall, the proposed segmentation method shows potential for an improved planning of LAA occlusion, demonstrating its added value for normal clinical practice.
dc.language.isoeng
dc.rightsopenAccess
dc.subjectCiências Tecnológicas, Ciências médicas e da saúde
dc.subjectTechnological sciences, Medical and Health sciences
dc.titleFast Segmentation of the Left Atrial Appendage in 3-D Transesophageal Echocardiographic Images
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1109/tuffc.2018.2872816
dc.identifier.authenticusP-00Q-1ZM
dc.subject.fosCiências médicas e da saúde
dc.subject.fosMedical and Health sciences
Aparece nas coleções:FEUP - Artigo em Revista Científica Internacional

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
304943.pdfPaper draft1.29 MBAdobe PDFThumbnail
Ver/Abrir
304943.1.png1st Page293.29 kBimage/pngThumbnail
Ver/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.