Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/110265
Full metadata record
DC FieldValueLanguage
dc.creatorAraliya Mosleh
dc.creatorH. Rodrigues
dc.creatorH. Varum
dc.creatorA. Costa
dc.creatorA. Arêde
dc.date.accessioned2025-05-11T23:06:54Z-
dc.date.available2025-05-11T23:06:54Z-
dc.date.issued2016
dc.identifier.othersigarra:136989
dc.identifier.urihttps://hdl.handle.net/10216/110265-
dc.description.abstractEarthquakes which recently occurred in highly populated regions show that existing buildings constructed without appropriate seismic resisting characteristics may constitute as an important source of risk and may cause economical loses and casualties. It is recognized the progress of the knowledge in earthquake engineering in the last decades. In this paper, two 6 irregular storey buildings were studied consisting of frame structures, representative of the common practice in Portugal, i.e. designed without considering earthquake actions. Push-over and non-linear time history analyses were done, with non-linear 3-D models in longitudinal and transverse directions. The building responses were analyzed in two different levels: global and local. For the global response analyses: max displacement, inter-storey drift (IS drift), floor rotation for each storey and base shear were compared. For local response four columns were chosen and the variation of axial load in terms of base shear and drift as well as the biaxial demand was considered. The result shows that most variation of axial load happens in corner, facade-X, facade-Y and centre column respectively. It is noteworthy that by increasing the initial axial load the biaxial demand decreases. The seismic vulnerability was analyzed for earthquake of different return periods, and the seismic demands were compared with limit proposed in international codes and conclusion are drafted in terms of safety. The vulnerability assessment based on seismic codes clearly shows that the building 2 presented a better performance with low inter-storey drifts. The main goal of this study is considering the application and methodology for the seismic assessment of existent real buildings. In fact this is an important topic, to understand the seismic vulnerability of certain particularities in existing buildings to assure that the common observation can be applied for a prototype building, especially irregular ones. Also one of the major observations in this study is the comprehension of the effect and importance of biaxial loading in columns and the influence of the axial load variation, relating the position of the columns in plan and in height.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectEngenharia estrutural, Engenharia civil
dc.subjectStructural engineering, Civil engineering
dc.titleSeismic behavior of RC building structures designed according to current codes
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/j.istruc.2016.04.001
dc.identifier.authenticusP-00K-JVG
dc.subject.fosCiências da engenharia e tecnologias::Engenharia civil
dc.subject.fosEngineering and technology::Civil engineering
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
136989.pdf
  Restricted Access
Artigo2.72 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.