dc.description.abstractInfill masonry (IM) walls are considered to be non-structural elements but, when subjected to earthquakes, they tend to interact with the surrounding RC (reinforced concrete) frames, which can result in different failure modes depending on the combination of the in-plane and out-of-plane behaviour. Therefore, the contribution of IM panels should be considered in the structural response analysis of existing buildings, for which an understanding of the out-of-plane non-linear behaviour of IM walls is of paramount importance in order to develop efficient strengthening solutions to prevent collapse and improve their performance in future earthquakes, and consequently reduce their seismic vulnerability. In order to obtain further knowledge of the out-of-plane response of IM panels, a study of full-scale IM walls was carried out with the realization of three experimental (cyclic and monotonic) out-of-plane tests with and without previous in-plane damage. The experiments, material characterization and the test set-up will be described in this paper as well as presenting and discussing the main test results, namely in terms of hysteretic force-displacement curves, damage evolution, stiffness degradation and energy dissipation.
dc.language.isoeng
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Programa de Financiamento Plurianual de Unidades de I&D/UID/ECI/04708/2013- POCI-01-0145-FEDER-007457/Instituto de I&D em Estruturas e Construções/CONSTRUCT
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Projectos de I&DT em Todos os Domínios Científicos/PTDC/ECM/122347/2010/Desenvolvimento de soluções inovadoras para reabilitação de paredes de enchimento/RetroInf
dc.rightsrestrictedAccess
dc.subjectEngenharia estrutural, Engenharia civil
dc.subjectStructural engineering, Civil engineering
dc.titleExperimental evaluation of out-of-plane capacity of masonry infill walls
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/j.engstruct.2015.12.013
dc.identifier.authenticusP-00K-23S
dc.subject.fosCiências da engenharia e tecnologias::Engenharia civil
dc.subject.fosEngineering and technology::Civil engineering
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
136991.pdf
  Restricted Access
Artigo4.5 MBAdobe PDF    Request a copy from the Author(s)


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.