Utilize este identificador para referenciar este registo:
https://hdl.handle.net/10216/103751Registo completo
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.creator | Guillaume L. Erny | |
| dc.creator | Marzieh Moeenfard | |
| dc.creator | Arminda Alves | |
| dc.date.accessioned | 2022-09-09T00:20:43Z | - |
| dc.date.available | 2022-09-09T00:20:43Z | - |
| dc.date.issued | 2015 | |
| dc.identifier.issn | 1615-9306 | |
| dc.identifier.other | sigarra:104796 | |
| dc.identifier.uri | https://hdl.handle.net/10216/103751 | - |
| dc.description.abstract | In this manuscript, the separation of kahweol and cafestol esters from Arabica coffee brews was investigated using liquid chromatography with a diode array detector. When detected in conjunction, cafestol, and kahweol esters were eluted together, but, after optimization, the kahweol esters could be selectively detected by setting the wavelength at 290 nm to allow their quantification. Such an approach was not possible for the cafestol esters, and spectral deconvolution was used to obtain deconvoluted chromatograms. In each of those chromatograms, the four esters were baseline separated allowing for the quantification of the eight targeted compounds. Because kahweol esters could be quantified either using the chromatogram obtained by setting the wavelength at 290 nm or using the deconvoluted chromatogram, those compounds were used to compare the analytical performances. Slightly better limits of detection were obtained using the deconvoluted chromatogram. Identical concentrations were found in a real sample with both approaches. The peak areas in the deconvoluted chromatograms were repeatable (intraday repeatability of 0.8%, interday repeatability of 1.0%). This work demonstrates the accuracy of spectral deconvolution when using liquid chromatography to mathematically separate coeluting compounds using the full spectra recorded by a diode array detector. | |
| dc.language.iso | eng | |
| dc.relation | info:eu-repo/grantAgreement/Autoridade de Gestão do Programa Operacional Regional do Norte/Programas Integrados de IC&DT/NORTE-07-0124-FEDER-000025/(Bio) Chemical Engineering: Multi-Scale Approaches for Sustainable Environment and Health/LEPAE/CEFT - RL2 | |
| dc.relation | info:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Projetos Estratégicos/PEst-C/EQB/UI0511/2013/PROJECTO ESTRATÉGICO - UI 511 - 2013-2014/UI0511 | |
| dc.rights | restrictedAccess | |
| dc.subject | Ciências Tecnológicas, Ciências da engenharia e tecnologias | |
| dc.subject | Technological sciences, Engineering and technology | |
| dc.title | Liquid chromatography with diode array detection combined with spectral deconvolution for the analysis of some diterpene esters in Arabica coffee brew | |
| dc.type | Artigo em Revista Científica Internacional | |
| dc.contributor.uporto | Faculdade de Engenharia | |
| dc.identifier.doi | 10.1002/jssc.201401095 | |
| dc.identifier.authenticus | P-00G-16Y | |
| dc.subject.fos | Ciências da engenharia e tecnologias | |
| dc.subject.fos | Engineering and technology | |
| Aparece nas coleções: | FEUP - Artigo em Revista Científica Internacional | |
Ficheiros deste registo:
| Ficheiro | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| 104796.1.pdf | Post-Print version | 1.08 MB | Adobe PDF | ![]() Ver/Abrir |
| 104796.pdf Restricted Access | Artigo original publicado | 3.23 MB | Adobe PDF | Ver/Abrir |
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.
