Utilize este identificador para referenciar este registo: https://hdl.handle.net/10216/103129
Registo completo
Campo DCValorIdioma
dc.creatorMónica S. F. Santos
dc.creatorLuís M. Madeira
dc.creatorArminda Alves
dc.date.accessioned2022-09-09T03:42:17Z-
dc.date.available2022-09-09T03:42:17Z-
dc.date.issued2014
dc.identifier.issn1759-9660
dc.identifier.othersigarra:93805
dc.identifier.urihttps://hdl.handle.net/10216/103129-
dc.description.abstractThe aim of this work was to develop an expeditious analytical methodology to evaluate the paraquat (PQ) contamination level in deposits from drinking water networks. To the best of our knowledge, no other study has focused on this matter, which is of crucial importance, for instance, to obtain a fast response after a suspicion of contamination (emergency situation). Three deposits representative of those typically found in drinking water networks were used: two iron-based - S2 and S3, and a calcium rich one - S4. The analytical method consists of an easy and fast extraction step, using a saturated ammonium chloride solution, followed by direct injection in a high performance liquid chromatograph with a diode array detector (HPLC-DAD). A matrix-matched calibration was performed for paraquat, in the range of 5 to 193 mu gPQ per g deposit, and a limit of detection of 0.1 mu gPQ per g deposit was reached. The good percentages of recovery (90-101% on average) and the tow relative standard deviations observed for the PQ-S3 system (3, 4 and 2% for 20, 80 and 160 mu gPQ per g deposit, respectively) enable a reliable quantification of paraquat, even at the lowest contamination levels. The developed analytical methodology can also be extended for diquat and also proved to be suitable for paraquat quantification in other types of deposits.
dc.language.isoeng
dc.relationinfo:eu-repo/grantAgreement/COMISSÃO EUROPEIA/7.º Programa-Quadro de IDT/217976 /Security and decontamination of drinking water distribution systems following a deliberate contamination /SECUREAU
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Projectos de I&DT em Todos os Domínios Científicos/PTDC/AAC-AMB/101687/2008/Segurança química em sistemas de abastecimento de água/ACQUASAFE
dc.rightsrestrictedAccess
dc.subjectCiências da engenharia e tecnologias
dc.subjectEngineering and technology
dc.titleParaquat quantification in deposits from drinking water networks
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1039/c4ay00121d
dc.identifier.authenticusP-009-GPB
dc.subject.fosCiências da engenharia e tecnologias
dc.subject.fosEngineering and technology
Aparece nas coleções:FEUP - Artigo em Revista Científica Internacional

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
93805.pdf
  Restricted Access
Artigo original publicado693.39 kBAdobe PDFVer/Abrir
93805.1.pdfPost-Print version299.95 kBAdobe PDFThumbnail
Ver/Abrir


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.