Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/103128
Full metadata record
DC FieldValueLanguage
dc.creatorMónica S. F.Santos
dc.creatorLuís M. Madeira
dc.creatorArminda Alves
dc.date.accessioned2022-09-07T16:53:49Z-
dc.date.available2022-09-07T16:53:49Z-
dc.date.issued2015
dc.identifier.issn1082-6076
dc.identifier.othersigarra:93806
dc.identifier.urihttps://hdl.handle.net/10216/103128-
dc.description.abstractThree analytical methodologies for paraquat (PQ) identification and quantification in waters were developed and validated in response to different scenarios: a direct injection-liquid chromatography-diode array detector (DI-LC-DAD) method for emergency situations, as occurs when there is a suspicion of contamination of drinking water networks; a solid phase extraction-liquid chromatography-diode array detector (SPE-LC-DAD) method to control the drinking water quality and a direct injection-liquid chromatography-mass spectrometry (DI-LC-MS) method for confirmation purposes and identification of PQ degradation by-products. Limits of detection of 10 mu g/L, 0.04 mu g/L, and 20 mu g/L PQ were reached for DI-LC-DAD, SPE-LC-DAD, and DI-LC-MS methods, respectively. The PQ analytical response of DI-LC-DAD method was tested in different types of water and in the presence of other species (Fe(II), H2O2 and Na2SO3) or compounds resulting from the contact of the water with deposits and Pseudomonas fluorescens cells that exist in drinking water networks. Additionally, the method response was assessed when Gramoxone was used as PQ source instead of the analytical standard. Global uncertainties below 6%, 11%, and 13% were found for DI-LC-MS, SPE-LC-DAD, and DI-LC-DAD, respectively, for the most part of the calibration ranges. All methods proved to be precise, accurate, and suitable for the purpose that they were designed.
dc.language.isoeng
dc.relationinfo:eu-repo/grantAgreement/COMISSÃO EUROPEIA/7.º Programa-Quadro de IDT/217976 /Security and decontamination of drinking water distribution systems following a deliberate contamination /SECUREAU
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e a Tecnologia/Projectos de I&DT em Todos os Domínios Científicos/PTDC/AAC-AMB/101687/2008/Segurança química em sistemas de abastecimento de água/ACQUASAFE
dc.rightsrestrictedAccess
dc.subjectCiências da engenharia e tecnologias
dc.subjectEngineering and technology
dc.titleDifferent approaches for paraquat quantification in waters
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1080/10826076.2014.913526
dc.identifier.authenticusP-009-ZZ3
dc.subject.fosCiências da engenharia e tecnologias
dc.subject.fosEngineering and technology
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
93806.1.pdfPost-Print version463.91 kBAdobe PDFThumbnail
View/Open
93806.pdf
  Restricted Access
Artigo original publicado1.14 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.