Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/103041
Full metadata record
DC FieldValueLanguage
dc.creatorGuillaume L. Erny
dc.creatorTanize Acunha
dc.creatorCarolina Simó
dc.creatorAlejandro Cifuentes
dc.creatorArminda Alves
dc.date.accessioned2019-08-29T23:15:07Z-
dc.date.available2019-08-29T23:15:07Z-
dc.date.issued2017
dc.identifier.issn0021-9673
dc.identifier.othersigarra:185441
dc.identifier.urihttps://hdl.handle.net/10216/103041-
dc.description.abstractSeparation techniques hyphenated with high-resolution mass spectrometry have been a true revolutionin analytical separation techniques. Such instruments not only provide unmatched resolution, but theyalso allow measuring the peaks accurate masses that permit identifying monoisotopic formulae. However, data files can be large, with a major contribution from background noise and background ions.Such unnecessary contribution to the overall signal can hide important features as well as decrease theaccuracy of the centroid determination, especially with minor features. Thus, noise and baseline correction can be a valuable pre-processing step. The methodology that is described here, unlike any otherapproach, is used to correct the original dataset with the MS scans recorded as profiles spectrum. Usingurine metabolic studies as examples, we demonstrate that this thorough correction reduces the datacomplexity by more than 90%. Such correction not only permits an improved visualisation of secondarypeaks in the chromatographic domain, but it also facilitates the complete assignment of each MS scanwhich is invaluable to detect possible comigration/coeluting species.
dc.language.isoeng
dc.relationinfo:eu-repo/grantAgreement/Comissão de Coordenação e Desenvolvimento Regional do Norte/P2020|Norte2020-Projetos Integrados ICDT/NORTE-01-0145-FEDER-000005/LEPABE-2-ECO-INNOVATION/LEPABE-2-ECO-INNOVATION
dc.relationinfo:eu-repo/grantAgreement/FCT - Fundação para a Ciência e Tecnologia/Projetos Estratégicos/UID/EQU/00511/2013 - POCI-01-0145-FEDER-006939/Laboratório de Engenharia de Processos, Ambiente, Biotecnologia e Energia/LEPABE
dc.rightsrestrictedAccess
dc.subjectQuímica analitica, Química
dc.subjectAnalytical chemestry, Chemical sciences
dc.titleBackground correction in separation techniques hyphenated to high-resolution mass spectrometry - Thorough correction with MS scans recorded as profile spectra
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/j.chroma.2017.02.052
dc.subject.fosCiências exactas e naturais::Química
dc.subject.fosNatural sciences::Chemical sciences
Appears in Collections:FEUP - Artigo em Revista Científica Internacional

Files in This Item:
File Description SizeFormat 
185441.pdf
  Restricted Access
Artigo original publicado1.67 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.