Please use this identifier to cite or link to this item: https://hdl.handle.net/10216/100395
Full metadata record
DC FieldValueLanguage
dc.creatorSara S. de Freitas
dc.creatorVasco P. de Freitas
dc.creatorEva Barreira
dc.date.accessioned2019-06-17T23:10:54Z-
dc.date.available2019-06-17T23:10:54Z-
dc.date.issued2014
dc.identifier.issn0950-0618
dc.identifier.othersigarra:142365
dc.identifier.urihttps://hdl.handle.net/10216/100395-
dc.description.abstractFacade plaster detachment is a pathology that spoils the appearance of the facade, facilitate rainwater penetration and consequently reduce durability. Infrared thermography can be successfully applied to a rapid non-destructive diagnosis provided that the multiple parameters involved are accounted. Results of laboratory and in situ tests to assess detachments using dynamic thermography are presented and compared with numerical simulation results. These pathologies become visible through the action of radiation from sunlight or a heat source once they create an air layer between the plaster and masonry, which causes additional thermal resistance, changing the temperature distribution in the areas with anomalies.
dc.language.isoeng
dc.rightsrestrictedAccess
dc.subjectEngenharia civil, Engenharia civil
dc.subjectCivil engineering, Civil engineering
dc.titleDetection of façade plaster detachments using infrared thermography - A nondestructive technique
dc.typeArtigo em Revista Científica Internacional
dc.contributor.uportoFaculdade de Engenharia
dc.identifier.doi10.1016/j.conbuildmat.2014.07.094
dc.identifier.authenticusP-009-RXW
dc.subject.fosCiências da engenharia e tecnologias::Engenharia civil
dc.subject.fosEngineering and technology::Civil engineering